Device Management
3.2 Configuring the Device
The serial console port implements RS232 DCE (Data Communication Equipment) on
a DB9 connector. The following is the pin-out for the port:
1
5
9
6
Figure 3.1
Serial DB9 Console Port
Pin
Name
Description
Reserved (Do Not Connect)
2
TX
Transmit Data
3
RX
Receive Data
Reserved (Do Not Connect)
5
GND
Signal Ground
6
Reserved (Do Not Connect)
7
Reserved (Do Not Connect)
8
Reserved (Do Not Connect)
9
Reserved (Do Not Connect)
Connected internally.
Connected internally.
Ethernet Ports
Connect any of the available Ethernet ports on the device to a management
switch and access the RUGGEDCOM RS900 console and Web interfaces via the
device's IP address. The factory default IP address for the RUGGEDCOM RS900 is
For more information about available ports, refer to
3.2
Configuring the Device
Once the device is installed and connected to the network, it must be configured. All
configuration management is done via the RUGGEDCOM RS900 interface. For more
information about configuring the device, refer to the
RUGGEDCOM ROS User Guide
associated with the installed software release.
3.3
Resetting the Device
The RUGGEDCOM RS900 can be reset (rebooted) using the
RESET
button. The
RESET
button is recessed and can only be reached using a pin or small screwdriver.
To reset the device, quickly press and release the
RESET
button with a pin.
18
RUGGEDCOM RS900
Installation Manual, 12/2020, C79000-G8976-1024-12