RUGGEDCOM RS8000
Installation Guide
Chapter 6
Certification
EMC and Environmental Type Tests
29
IEEE 1613 (C37.90.x) EMC Immunity Type Tests
NOTE
The RUGGEDCOM RS8000 meets Class 2 requirements for an all-fiber configuration and Class 1
requirements for copper ports.
IEEE Test
IEEE 1613 Clause
Description
Test Levels
Enclosure Contact
±8 kV
C37.90.3
9
ESD
Enclosure Air
±15 kV
C37.90.2
8
Radiated RFI
Enclosure ports
35 V/m
Signal ports
±4 kV @ 2.5 kHz
DC Power ports
±4 kV
AC Power ports
±4 kV
Fast Transient
Earth ground ports
±4 kV
Signal ports
2.5 kV common mode @ 1MHz
DC Power ports
2.5 kV common and
differential mode @ 1MHz
C37.90.1
7
Oscillatory
AC Power ports
2.5 kV common and
differential mode @ 1MHz
Signal ports
5 kV (Failsafe Relay)
DC Power ports
5 kV
HV Impulse
AC Power ports
5 kV
Signal ports
2 kVAC (Failsafe Relay)
DC Power ports
1.5 kVDC
C37.90
6
Dielectric
Strength
AC Power ports
2 kVAC
Environmental Type Tests
Test
Description
Test Levels
Severity Levels
IEC 60068-2-1
Cold Temperature
Test Ad
-40 °C (-40 °F), 16 Hours
IEC 60068-2-2
Dry Heat
Test Bd
85 °C (185 °F), 16 Hours
IEC 60068-2-30
Humidity (Damp
Heat, Cyclic)
Test Db
95% (non-condensing),
55 °C (131 °F), 6 cycles
IEC 60255-21-1
Vibration
2 g @ 10-150 Hz
Class 2
IEC 60255-21-2
Shock
30 g @ 11 ms
Class 2
Summary of Contents for RUGGEDCOM RS8000
Page 4: ...RUGGEDCOM RS8000 Installation Guide iv ...
Page 10: ...Preface RUGGEDCOM RS8000 Installation Guide x Customer Support ...
Page 16: ...Chapter 1 Introduction RUGGEDCOM RS8000 Installation Guide 6 Supported Fiber Optic Cables ...
Page 28: ...Chapter 4 Communication Ports RUGGEDCOM RS8000 Installation Guide 18 ...
Page 34: ...Chapter 5 Technical Specifications RUGGEDCOM RS8000 Installation Guide 24 Dimension Drawings ...