Page 1: ...Edition 04 2021 Installation Manual SIMATIC NET Rugged Ethernet Switches RUGGEDCOM RMC41 https www siemens com ...

Page 2: ...C NET Rugged Ethernet Switches RUGGEDCOM RMC41 Installation Manual Preface Introduction 1 Installing the Device 2 Communication Ports 3 Technical Specifications 4 Certification 5 04 2021 C79000 G8976 1010 11 ...

Page 3: ...ied personnel are those who based on their training and experience are capable of identifying risks and avoiding potential hazards when working with these products systems Proper Use of Siemens Products Note the following WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation If products and components from other manufact...

Page 4: ... 1 Mounting the Device on a DIN Rail 7 2 3 2 Mounting the Device to a Panel 9 2 4 Connecting Power 9 2 4 1 Connecting AC Power 10 2 4 2 Connecting DC Power 12 3 Communication Ports 13 3 1 Copper Ethernet Ports 13 3 2 Fiber Optic Ethernet Ports 15 4 Technical Specifications 17 4 1 Power Supply Specifications 17 4 2 Copper Ethernet Port Specifications 17 4 3 Fiber Optic Ethernet Port Specifications ...

Page 5: ...1 CSA 21 5 1 2 European Union EU 21 5 1 3 FCC 22 5 1 4 FDA CDRH 22 5 1 5 ISED 22 5 1 6 ISO 22 5 1 7 RoHS 23 5 1 8 Other Approvals 23 5 2 EMC and Environmental Type Tests 23 iv RUGGEDCOM RMC41 Installation Manual 04 2021 C79000 G8976 1010 11 ...

Page 6: ...purchase conditional upon the return to factory for maintenance during the warranty term This product contains no user serviceable parts Attempted service by unauthorized personnel shall render all warranties null and void The warranties set forth in this article are exclusive and are in lieu of all other warranties performance guarantees and conditions whether written or oral statutory express or...

Page 7: ...s Sales representative Customer Support Customer support is available 24 hours 7 days a week for all Siemens customers For technical support or general information contact Siemens Customer Support through any of the following methods Online Visit http www siemens com automation support request to submit a Support Request SR or check on the status of an existing SR Telephone Call a local hotline ce...

Page 8: ...escent Concord Ontario Canada L4K 5C7 Telephone Toll free 1 888 264 0006 Tel 1 905 856 5288 Fax 1 905 856 1995 E Mail ruggedcom info i ia siemens com Web https www siemens com RUGGEDCOM RMC41 Installation Manual 04 2021 C79000 G8976 1010 11 vii ...

Page 9: ...Preface Contacting Siemens viii RUGGEDCOM RMC41 Installation Manual 04 2021 C79000 G8976 1010 11 ...

Page 10: ...rtation systems applications The versatility and wide selection of fiber optics allows the RUGGEDCOM RMC41 to be used in a variety of applications It can be used in place of traditional copper to fiber media converters with the added ability to convert speed from 10Mbps to 100Mbps 1 1 Feature Highlights Ethernet Ports with Optional Dual Fiber Optics 1 x 10 100Base TX ports and 1 x 100Base FX port ...

Page 11: ...collisions or dropped packet 1 2 Description The RUGGEDCOM RMC41 features various ports controls and indicator LEDs on the display panel for connecting configuring and troubleshooting the device The display panel can be located on the rear front or top of the device depending on the mounting configuration 6 4 3 5 1 2 1 POWER LED 2 Copper Ethernet Port with LEDs 3 Fiber Optic Ethernet Port ST Port ...

Page 12: ...head screwdriver For mounting the device to a DIN rail Phillips screwdriver For mounting the device to a panel 4 x 8 32 screws For mounting the device to a panel 1 4 Decommissioning and Disposal Proper decommissioning and disposal of this device is important to prevent malicious users from obtaining proprietary information and to protect the environment Decommissioning This device may include sens...

Page 13: ...itions Distance m Cable Type Wavelength nm Modal Bandwidth MHz km 100Base FX 1000Base SX 10GBase SR 850 200 275 33 OM1 62 5 125 1300 500 2000 850 500 550 82 OM2 50 125 1300 500 2000 850 1500 550 300 OM3 50 125 a 1300 500 2000 850 3500 550 400 OM4 50 125 a 1300 500 2000 a Laser optimized 4 RUGGEDCOM RMC41 Installation Manual 04 2021 C79000 G8976 1010 11 ...

Page 14: ...iation exposure CAUTION Burn hazard risk of serious personal injury The surface of the device may be hot during operation or as a result of the ambient air temperature Wear appropriate personal protective equipment and use caution when working with or around the device NOTICE This product contains no user serviceable parts Attempted service by unauthorized personnel shall render all warranties nul...

Page 15: ...he operating mode 4 Connect power to the device and ground the device to safety Earth 5 Connect the device to the network 6 Configure the device 2 2 Unpacking the Device When unpacking the device do the following 1 Inspect the package for damage before opening it 2 Visually inspect each item in the package for any physical damage 3 Verify all items are included Note If any item is missing or damag...

Page 16: ...pter preinstalled on the back of the chassis Use the adapter to mount the device to a standard 35 mm 1 4 in IEC EN 60715 or TS35 DIN rail Mounting the Device To mount the device to a DIN rail do the following 1 Hook the top teeth of the adapter onto the DIN rail Note The adapter features a sliding release with a slot at the bottom for a flathead screwdriver 2 3 2 1 1 1 1 DIN Rail 2 DIN Rail Adapte...

Page 17: ...ng 1 Insert a flathead screwdriver into the slot of the sliding release and move it down 1 2 2 1 1 3 1 DIN Rail 2 DIN Rail Adapter Figure 2 2 Removing the Device from a DIN Rail 2 Swing the bottom of the device away from the DIN rail 3 Lift the device off the DIN rail 8 RUGGEDCOM RMC41 Installation Manual 04 2021 C79000 G8976 1010 11 ...

Page 18: ...s 4 Screw 5 Metal Clips Figure 2 3 Panel Mounting 2 Place the panel adapter against the panel and align the adapater with the mounting holes 3 Secure the panel adapter using three 6 32 screws 4 Insert the device into the adapter Make sure the device is secured between the two metal clips 5 Install the screw previously removed from the bottom of the panel adapter 2 4 Connecting Power The RUGGEDCOM ...

Page 19: ...Note Siemens requires the use of external surge protection in VDSL applications where the line may be subject to surges greater than that for which the device is rated Use the following specifications as a guide for VDSL external surge protection Clamping Voltage 50 V to 200 V Insertion Loss 0 1 dB at 10 MHz Peak Surge Current 10 kA 8x20µs waveform 2 4 1 Connecting AC Power To connect a high AC po...

Page 20: ... negative wire from the power source to the negative neutral N terminal on the terminal block 3 Using a braided wire or other appropriate grounding wire connect the surge ground terminal to the chassis ground connection The surge ground terminal is used as the ground conductor for all surge and transient suppression circuitry internal to the unit 4 Connect the ground terminal on the power source t...

Page 21: ...he power source to the positive live L terminal on the terminal block 1 2 3 4 1 Positive Live L Terminal 2 Negative Neutral N Terminal 3 Surge Ground Terminal 4 Braided Ground Cable Figure 2 5 Terminal Block Wiring 2 Connect the negative wire from the power source to the negative neutral N terminal on the terminal block 3 Using a braided wire or other appropriate grounding wire connect the surge g...

Page 22: ...ber Optic Ethernet Port 3 1 Copper Ethernet Ports The RUGGEDCOM RMC41 supports two 10 100Base TX Ethernet ports that allow connection to a standard Category 5 CAT 5 unshielded twisted pair UTP cable with an RJ45 male connector The RJ45 receptacles are directly connected to the chassis ground on the device and can accept CAT 5 shielded twisted pair STP cables RUGGEDCOM RMC41 Installation Manual 04 ...

Page 23: ...uring line to ground fault conditions LEDs Each port features a 100 and Link Act LED that indicates the state of the port LED State Description Yellow The port is operating at 100 Mbps 100 Off The port is operating at 10 Mbps Yellow Solid Link established Yellow Blinking Link activity Link Act Off No link detected Pin Out The following is the pin out for the RJ45 male connectors 8 1 Figure 3 2 RJ4...

Page 24: ... and Receive Rx connections of each port are properly connected and matched to establish a proper link Available Ports 2 1 1 Tx Connector 2 Rx Connector Figure 3 3 SC Port 2 1 1 Tx Connector 2 Rx Connector Figure 3 4 ST Port Specifications For specifications on the available fiber optic Ethernet ports refer to Fiber Optic Ethernet Port Specifications Page 17 RUGGEDCOM RMC41 Installation Manual 04 ...

Page 25: ...Communication Ports 3 2 Fiber Optic Ethernet Ports 16 RUGGEDCOM RMC41 Installation Manual 04 2021 C79000 G8976 1010 11 ...

Page 26: ...he following details the specifications for copper Ethernet ports that can be ordered with the RUGGEDCOM RMC41 Speed a 10 100Base TX Connector RJ45 Duplex a FDX HDX Cable Type b CAT 5 Wiring Standard c TIA EIA T568A B Maximum Distance d 100 m 328 ft Isolation e 1 5 kV a Auto negotiating b Shielded or unshielded c Auto crossover and auto polarity d Typical distance Dependent on the number of connec...

Page 27: ...MM SC 62 5 125 1300 1300 19 14 30 14 2 5 155 Mbps SM SC 9 125 1310 1310 5 0 35 3 40 155 Mbps SM SC 9 125 1310 1310 0 5 37 3 90 a Typical b Operating temperature 10 to 85 C 14 to 185 F 4 4 Supported Networking Standards Parameter 10Base FL 100Base FX Notes IEEE 802 3 Yes 10Base T IEEE 802 3u Yes 100Base TX 100Base FX IEEE 802 3x Yes Yes Full Duplex Flow Control 4 5 Operating Environment Parameter R...

Page 28: ...68 kg 1 5 lbs Ingress Protection IP30 Enclosure 21 AWG Galvanized Steel 4 7 Dimension Drawings Note All dimensions are in millimeters unless otherwise stated 70 7 90 4 80 1 73 7 62 2 58 4 109 0 99 3 Figure 4 1 Overall Dimensions RUGGEDCOM RMC41 Installation Manual 04 2021 C79000 G8976 1010 11 19 ...

Page 29: ...l Specifications 4 7 Dimension Drawings 121 7 113 8 105 7 57 2 4 0 11 4 35 6 58 4 62 2 67 3 109 0 92 5 82 2 Figure 4 2 Panel Mount Dimensions 20 RUGGEDCOM RMC41 Installation Manual 04 2021 C79000 G8976 1010 11 ...

Page 30: ...2368 1 UL 62368 1 Information Technology Equipment Safety Part 1 General Requirements 5 1 2 European Union EU This device is declared by Siemens AG to comply with essential requirements and other relevant provisions of the following EU directives EN 62368 1 Information Technology Equipment Safety Part 1 General Requirements EN 61000 6 2 Electromagnetic Compatibility EMC Part 6 2 Generic Standards ...

Page 31: ...mful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference on his own expense 5 1 4 FDA CDRH This device meets the requirements of the following U S Food and Drug Administration FDA standard Title 21 Code of Federal Regulations CFR Chapter I Sub chapter J Rad...

Page 32: ...tandard Environmental and Testing Requirements for Communications Networking Devices in Electric Power Substations IEC 61850 3 Communications Networks and Systems for Power Utility Automation Part 3 General Requirements 5 2 EMC and Environmental Type Tests The RUGGEDCOM RMC41 has passed the following EMC and environmental tests IEC 61850 3 Type Tests Test Description Test Levels Severity Levels En...

Page 33: ...riods IEC 61000 4 11 Voltage Dips and Interrupts AC Power Ports 100 for 5 periods 100 for 50 periods Signal Ports 2 kV Fail Safe Relay output DC Power Ports 1 5 kV Dielectric Strength AC Power Ports 2 kV Signal Ports 5 kV Fail Safe Relay Output DC Power Ports 5 kV IEC 60255 5 HV Impulse AC Power Ports 5 kV a Siemens specified severity level IEEE 1613 EMC Immunity Type Tests Note The RUGGEDCOM RMC4...

Page 34: ...kV HV Impulse AC Power Ports 5 kV Signal Ports 2 kV DC Power Ports 1 5 kV Dielectric Strength AC Power Ports 2 kV Environmental Type Tests Test Description Test Levels Severity Levels IEC 60068 2 1 Cold Temperature Test Ad 40 C 40 F 16 Hours IEC 60068 2 2 Dry Heat Test Bd 85 C 185 F 16 Hours IEC 60068 2 30 Humidity Damp Heat Cyclic Test Db 95 non condensing 55 C 131 F 6 cycles IEC 60255 21 1 Vibra...

Page 35: ...Certification 5 2 EMC and Environmental Type Tests 26 RUGGEDCOM RMC41 Installation Manual 04 2021 C79000 G8976 1010 11 ...

Page 36: ...ttps www siemens com ruggedcom Industry Online Support service and support https support industry siemens com Industry Mall https mall industry siemens com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY ...