Technical Specifications
4.4 Supported Networking Standards
Note
• All optical power numbers are listed as dBm averages. To convert from average
to peak add 3 dBm. To convert from peak to average, subtract 3 dBm.
• Maximum segment length is greatly dependent on factors such as fiber quality,
and the number of patches and splices. Consult a Siemens Sales associate when
determining maximum segment distances.
Wavelength (nm)
Transmit
Power (dBm)
Data
Rate
Mode Connector Cable
(μm)
Transmit Receive
Min
Max
Receiver
Sensitivity
(dBm)
Receiver
Saturation
(dBm)
Distance
100
Mbps
SM
SC
9/125
1300
1300
-15
-8
-31
-7
15
100
Mbps
MM
ST
62.5/125
1300
1300
-19
-14
-30
-14
2.5
100
Mbps
MM
SC
62.5/125
1300
1300
-19
-14
-30
-14
2.5
155
Mbps
SM
SC
9/125
1310
1310
-5
0
-35
-3
40
155
Mbps
SM
SC
9/125
1310
1310
0
5
-37
-3
90
Typical.
Operating temperature: -10 to 85 °C (14 to 185 °F)
4.4
Supported Networking Standards
Parameter
10Base-FL
100Base-FX
Notes
IEEE 802.3
Yes
10Base-T
IEEE 802.3u
Yes
100Base-TX/100Base-FX
IEEE 802.3x
Yes
Yes
Full Duplex, Flow Control
4.5
Operating Environment
Parameter
Range
Comments
Ambient Operating
-40 to 85 °C
(-40 to 185 °F)
Measured from a 30 cm (12 in) radius
surrounding the center of the enclosure.
Ambient Relative Humidity
5% to 95%
Non-condensing
Ambient Storage Temperature
-40 to 85 °C
(-40 to 185 °F)
Typical. May change based on which fiber optic transceivers are installed. For more information, refer to
"Fiber Optic Ethernet Port Specifications (Page 17)"
.
18
RUGGEDCOM RMC41
Installation Manual, 04/2021, C79000-G8976-1010-11