Chapter 6
Certification
RUGGEDCOM RMC
Installation Guide
26
EMC and Environmental Type Tests
Test
Description
Test Levels
Severity Levels
40 A/m continuous, 1000 A/m for 1 s
Note
a
IEC 61000-4-8
Magnetic Field
Enclosure Ports
1000 A/m for 1 s
5
DC Power Ports
30% for 0.1 s, 60% for
0.1 s, 100% for 0.05 s
IEC 61000-4-29
30% for 1 period, 60% for 50 periods
IEC 61000-4-11
Voltage Dips and Interrupts
AC Power Ports
100% for 5 periods,
100% for 50 periods
Signal Ports
2 kV (Fail-Safe Relay output)
DC Power Ports
1.5 kV
Dielectric Strength
AC Power Ports
2 kV
Signal Ports
5 kV (Fail-Safe Relay Output)
DC Power Ports
5 kV
IEC 60255-5
HV Impulse
AC Power Ports
5 kV
a
Siemens specified severity level.
IEEE 1613 EMC Immunity Type Tests
NOTE
The RUGGEDCOM RMC meets Class 2 requirements for an all-fiber configuration and Class 1
requirements for copper ports.
Description
Test Levels
Enclosure Contact
± 8 kV
ESD
Enclosure Air
± 15 kV
Radiated RFI
Enclosure Ports
35 V/m
Signal Ports
± 4 kV @ 2.5 kHz
DC Power Ports
± 4 kV
AC Power Ports
± 4 kV
Fast Transient
Earth Ground Ports
± 4 kV
Signal Ports
2.5 kV common mode @ 1MHz
DC Power Ports
2.5 kV common, 1 kV differential mode @ 1MHz
Oscillatory
AC Power Ports
2.5 kV common, 1 kV differential mode @ 1MHz
Signal Ports
5 kV (Failsafe Relay)
DC Power Ports
5 kV
HV Impulse
AC Power Ports
5 kV
Signal Ports
2 kV
Dielectric Strength
DC Power Ports
1.5 kV