RUGGEDCOM RMC
Installation Guide
Chapter 2
Installing the Device
Mounting the Device to a Panel
7
Section 2.1.2
Mounting the Device to a Panel
To mount the device to a panel, do the following:
1. Place the panel adapter against the panel and secure it with screws.
113
12
4
4
5
1
Figure 3: Panel Mounting
1.
RUGGEDCOM RMC
2.
Panel Adapter
3.
Mounting Holes
4.
Screw
5.
Metal Clips
2. Insert the device into the adapter. Make sure the device is secured between the two metal clips.
Section 2.2
Connecting Power
The RUGGEDCOM RMC supports a single integrated high AC/DC or low DC power supply
NOTE
• For 110/230 VAC rated equipment, an appropriately rated AC circuit breaker must be installed.
• For 125/250 VDC rated equipment, an appropriately rated DC circuit breaker must be installed.
• Use only #16 gage copper wiring when connecting terminal blocks.
• Equipment must be installed according to applicable local wiring codes and standards.