RUGGEDCOM NETCONF
Reference Guide
Chapter 6
RUGGEDCOM ROX II Actions
reset (Cellular Modem)
63
</modem>
</interfaces>
</data>
</action>
</rpc>]]>]]>
•
{interfaceName}
The name of the modem interface.
•
{atCommand}
The AT command to send to the modem. The command must begin with the prefix AT.
Section 6.2.3
reset (Cellular Modem)
This action resets the cellular modem. Specify the modem module and port in the
<module>
and
<port>
elements. This action does not take any parameters.
<rpc message-id="101" xmlns="urn:ietf:params:xml:ns:netconf:base:1.0">
<action xmlns="http://tail-f.com/ns/netconf/actions/1.0">
<data>
<interfaces xmlns="http://ruggedcom.com/ns/rmf_ifs">
<cellmodem>
<module>{module}</module>
<port>{port}</port>
<reset/>
</cellmodem>
</interfaces>
</data>
</action>
</rpc>]]>]]>
•
{module}
The module number for the cellular modem.
•
{port}
The port number for the cellular modem.
Section 6.2.4
at (Cellular Modem)
This action sends an AT command to the cellular modem. The command must begin with the prefix AT. Specify
the modem module and port in the
<module>
and
<port>
elements. This action takes a single parameter:
<command>
.
<rpc message-id="101" xmlns="urn:ietf:params:xml:ns:netconf:base:1.0">
<action xmlns="http://tail-f.com/ns/netconf/actions/1.0">
<data>
<interfaces xmlns="http://ruggedcom.com/ns/rmf_ifs">
<cellmodem>
<module>{module}</module>
<port>{port}</port>
<at>
<command>{atCommand}</command>
</at>
Summary of Contents for RUGGEDCOM MX5000RE
Page 8: ...Table of Contents RUGGEDCOM NETCONF Reference Guide viii ...
Page 12: ...Preface RUGGEDCOM NETCONF Reference Guide xii Customer Support ...
Page 26: ...Chapter 1 Introduction RUGGEDCOM NETCONF Reference Guide 14 Sample Session Editing Data ...
Page 40: ...Chapter 3 NETCONF Sessions RUGGEDCOM NETCONF Reference Guide 28 Killing a Session ...
Page 64: ...Chapter 5 Changing Configuration Data RUGGEDCOM NETCONF Reference Guide 52 Committing Changes ...
Page 148: ...Chapter 8 NETCONF XML Elements RUGGEDCOM NETCONF Reference Guide 136 validate ...