11 / 13
Siemens
RDD100.1RFS Wireless room thermostat with LCD
CB1N1424en
Building Technologies
2017-11-21
Connection diagrams
Q11
Q14
N2
L
N
Q12
A
C
2
30
V
A
C
24
..
.2
3
0
V
Lx
Nx
N
L
Y1
8 (2) A
Max.
T
L
L
N1
1
4
2
4
A
0
1
10 A
10 A
L
Live, AC 230 V
Q11 Live, AC 24…230 V
Q14
NO contact, AC
24…230 V/8(2) A
Q12
NC contact, AC
24…230 V/8(2) A
N
Neutral conductor
Nx
Neutral conductor
N1 Transmitter
RDD100.1RF
N2
Receiver RCR100RF
Y1 Actuating
device
L – N AC 230 V/Lx – Nx AC 24…230 V
Application examples
T
T
F1
F2
N2
M1
Y2
1
42
4
S
0
1
N1
T
F1
F2
N2
M1
Y2
1
4
2
4
S
0
2
T
T
T
N1
Wireless room thermostat with receiver,
control of a gas-fired wall-hung boiler
Wireless room thermostat with receiver,
control of a gas-fired floor-standing
boiler
Y1
14
24
S
03
M1
N2
T
N1
F1
Thermal reset limit thermostat
F2
Safety limit thermostat
M1
Circulating pump
N1
RDD100.1RF room thermostat
N2
RCR100RF receiver
Y1
3-port valve with manual
adjustment
Y2
Magnetic valve
Wireless room thermostat with receiver,
control of a heating circuit pump
(precontrol by manual mixing valve)