6 / 9 

Siemens 

RDD100.1DHW   Room thermostat with independent DHW control 

CB1N1421en_01 

Building Technologies 

 

2013-03-14 

(From the calculation – assuming 4 operations per day on the thermostat, the esti-
mated 1-second scanning rate results in a battery life of 1 year. If the user in-
creases the scanning rate, the batteries’ life is extended.) 

 

If the battery symbol 

 appears, the batteries are almost exhausted and should 

be replaced. Use alkaline batteries type AAA. 
 
 

Operating notes 

The RDD100.1DHW provides Comfort, Economy and Protection mode. The differ-
ence between Comfort and Economy mode is only the room temperature setpoint. 
The changeover between Comfort, Economy and Protection mode is made by 
pressing touchkey 

When Comfort mode is activated, symbol   appears on the display. The setpoint 
(20 ºC) can be readjusted by pressing touchkeys 

+

 

and 

 
When Economy mode is activated, symbol   appears on the display. The setpoint 
(16 ºC)

 

can be readjusted by pressing touchkeys 

+

 

and 

.  

 
If the temperature falls below 5 ºC, the unit automatically activates the heating out-
put. The symbol   appears only, if the icon is enabled via parameter settings.  

 

When this DHW function is activated, symbol 

 appears on LCD.  

 
 

Maintenance notes 

The thermostats are maintenance-free. 
 
 

Disposal 

 

In terms of disposal, the room thermostats are classified as electronic scrap con-
forming to the European Directive 2011/65/EU (WEEE) and must not be disposed 
of as unsorted domestic waste. The relevant national legal regulations must be 
complied with and the units must be disposed of via the appropriate channels. 
Local and currently valid legislation must be observed. 

Technical data 

Operating voltage 

  RDD100.1DHW 

                      

 
DC 3 V (2 x 1.5 V alkaline batteries AAA) 

For battery life (RDD100.1DHW), see below (alkaline batteries type AAA). 
Battery life calculation is based on the touchpad scanning rate during idle time 
(assuming a user presses 4 touchkeys per day): 
Scanning rate 0.25 s 
Scanning rate 0.50 s                            
Scanning rate 1.00 s     
Scanning rate 1.50 s   

193 days battery life  
273 days battery life 
345 days battery life 
378 days battery life 

Change of batteries  

Comfort mode    

Economy mode   

Protection mode   

DHW 

  

 Power supply 

Summary of Contents for RDD100.1 DHW

Page 1: ... Off control of DHW Comfort Economy and Protection mode Adjustable commissioning and control parameters Battery powered DC 3 V 2 x 1 5 V AAA Use The RDD100 1DHW is used to control the room temperature in heating systems with independent control of DHW Typical applications Apartments For the control of the following plant components and of DHW Thermal valves or zone valves Gas or oil boilers Fans P...

Page 2: ...ol parameters Independent DHW Temperature control The unit acquires the room temperature with its built in sensor and maintains the setpoint by delivering control commands The switching differential is 1 K Q14 T C ON OFF W SD 1421D01 T Room temperature SD Switching differential W Room temperature setpoint Q14 Output signal for heating Type summary Product No Stock No Features RDD100 1DHW S55770 T2...

Page 3: ...h screw terminals The housing engages in the mounting plate and is secured with a screw 1 Operating mode touchkey 2 Touchkey for increasing a value 3 Touchkey for decreasing a value 4 DHW switch On Off touchkey Description Product No Data Sheet Electromotoric actuator SFA21 4863 Electrothermal actuator for radiator valves STA23 4884 Electrothermal actuator for small valves 2 5 mm STP23 4884 Damper...

Page 4: ...ption 1 Indicating that batteries need to be replaced 6 F Room temperature in degrees Fahrenheit 2 Protection mode protection mode symbol can be enabled via parameter settings 7 Touchkey lock activated 3 Comfort mode 8 C Room temperature in degrees Celsius 4 Economy mode 9 Heating On 5 Display of room temperature setpoint etc 10 DHW On 11 Current room temperature Display ...

Page 5: ...h all LCD segments flash indicating that reset was made correctly After the reset the ther mostat is ready for commissioning by qualified HVAC personnel The control parameters of the thermostat can be set to ensure optimum perform ance of the entire system Please refer to Operating Instructions CB1B1421 sec tion Do you want to change parameters If the temperature on the display does not agree with...

Page 6: ...erature falls below 5 ºC the unit automatically activates the heating out put The symbol appears only if the icon is enabled via parameter settings When this DHW function is activated symbol appears on LCD Maintenance notes The thermostats are maintenance free Disposal In terms of disposal the room thermostats are classified as electronic scrap con forming to the European Directive 2011 65 EU WEEE...

Page 7: ...ity As per IEC 60721 3 3 Class 3K5 0 50 C 95 r h Transport Climatic conditions Temperature Humidity Mechanical conditions As per IEC 60721 3 2 Class 2K3 25 60 C 95 r h Class 2M2 Storage Climatic conditions Temperature Humidity As per IEC 60721 3 1 Class 1K3 25 60 C 95 r h conformity to EMC directive Low voltage directive 2004 108 EC 2006 95 EC C Tick conformity to EMC emission standard AS NSZ 4251...

Page 8: ... N1 M1 Y2 1421S02 T T DHW Room thermostat with direct control of a gas fired wall hung boiler with inde pendent control of DHW Room thermostat with direct control of a gas fired floor standing boiler with in dependent control of DHW T N1 Y1 1421S03 M1 DHW F1 Thermal reset limit thermostat F2 Safety limit thermostat M1 Circulating pump N1 RDD100 1DHW room thermostat Y1 Mixing 3 port valve with manu...

Page 9: ...127 21 5 83 5 4 1 7 1 0 5 Ø80 Ø60 1421M01 Remarks Heating Because of the unavoidable self heating effects of the electrical current any loads of more than 3 Amperes connected to the unit can influence the control behavior and temperature accuracy in a negative way All dimensions in mm 2013 Siemens Switzerland Ltd Subject to change ...