background image

B2812en 

4 319 2285 0 g 

07.05.2013 

Programming  

To program the room unit, the unit cover must be open! 

As soon as the cover is opened, the display and the button function will 
change. The framed number indicates the program line that can be se-
lected with the arrow buttons 

 and 

28

12Z13

1

2

3

4

 

 
 
1 Line 

number 

2 Value 
3 Changing 

values 

4  Selecting line numbers 

You can set or display the following values: 

 Temperatures 

 

to 

 

 Heating 

program 

 

to 

 

  Weekday and clock 

 

to 

 

  Set day values 

 

 

 

 Holiday 

period 

 

 

 

  Resetting to the default values 

 

 

 

Setting the temperatures 

In the automatic mode, the room unit switches between the nominal and 
the reduced room temperature according to the heating program. 
In manual operation, the temperatures are switched by pressing the pres-
ence button. 

 

 

Nominal temperature:

 

Room temperature during room occupancy times (basic 
setting). 

 

 

Reduced temperature:

 

Room temperature during absence or in the night 

Heating program 

With the heating program, the temperature changeover times can be pre-
determined for one week. 
The seven-day program consists of a seven-day block (1-7) in which every 
day uses the same 24-hour program, or single days (1…7) with seven in-
dividual 24-hour programs (1 = Monday…7 = Sunday). Each 24-hour pro-
gram offers three heating periods each of which is defined by a start and 
an end time.  

If you do not use a heating period, let the start and the end times coincide. 

0

4

8

12

16

20

24

1

2273

Z

07

3

2

 

 

Select the respective day for the heating period. You have the 
choice of the seven-day block (1-7) and of individual days (1…7) 
(1 = Monday…   7 = Sunday) 

 

Start of period 1: 

Heating to the nominal temperature 

 

End of period 1: 

Heating to the reduced temperature 

 

Start of period 2: 

Heating to the nominal temperature 

 

End of period 2: 

Heating to the reduced temperature 

 

Start of period 3: 

Heating to the nominal temperature 

 

End of period 3: 

Heating to the reduced temperature 

Setting the time of day 

 

For setting the current weekday 
(1 = Monday…7 = Sunday) 

 

For setting the current minute 

Press buttons 

 and 

, to set the current time of day. Continuous 

pressing accelerates the display. 

If a central unit is used, the room unit’s clock will be synchronized with 
the system’s clock and the setting on the room unit locked (display 
OFF). 

Set day values 

 

Display of the set day values of all connected meters 

Press buttons 

 and 

 , to select the required meter, which the 

display shows as a symbol.  
The set day (billing day) is entered by the heating engineer. On that day, 
the system updates the set day values. 

Holiday function 

 

For entering the number of days during which you will be absent. 
The holiday function will be activated by closing the unit cover. 
The display shows the holiday symbol 

, the symbol for standby 

, the day of switching on, on the left (1 = Monday… 

7 = Sunday) and the number of days of the holiday period. 

 

 

During the holiday period, the room unit is in the standby mode 

 

On completion of the number of days entered, the room unit will 
switch to the automatic mode 

The holiday function can be cancelled by pressing any of the holiday mode 
buttons. 

Default values 

 

To retrieve the default values, press buttons 

 and 

 si-

multaneously for at least 3 seconds. As a confirmation, the display 
will show 

¦

 Caution: 

In that case, the following line numbers that have previously been en-
tered will be lost: 

  Temperature and time program 

 to 

 

  Duration of the holiday period 

 

Detection of airing 

In operating mode  , the room unit detects airing if the room temperature 
falls suddenly. 
In that case, the heating will temporarily be switched to standby   and 
symbol 

 appears. 

The room unit returns to operating mode    when: 

  The room temperature rises again 

  The operating mode changes 

  45 minutes have elapsed 

Central unit 

If a central unit is used, the room unit may be affected in the following way: 

  Limitation of settings 

  Central night setback 

  Clock setting locked 

Status displays 

Display: 

2312Z21

 

 

 

Clock setting locked, time of day centrally 
preset  

 

Programming lock active (to be set by the 
heating engineer) 

Display: 

2312Z22

 

 

 

Room unit faulty 

Display: 

2312Z23

 

 

 

External contact active. Do not press operat-
ing mode and presence button 

 