Siemens OP121 Installation Instructions Download Page 4

Siemens Industry, Inc.
Smart Infrastructure
8, Fernwood Road
Florham Park, New Jersey 07932
www.siemens.com/buildingtechnologies

Siemens Canada Limited
Smart Infrastructure
2 Kenview Boulevard
Brampton, Ontario L6T 5E4
Canada

© Siemens Industry, Inc.

Data and design subject to change without notice.

A6V10281367_d_en_--

P/N A5Q00039609

OP121

Figure 4

Figure 5

TM121 Test Magnet

Magnet Placement

OH121

Figure 6

Figure 7

TM121 Test Magnet

Magnet Placement

  Testing with the magnet only tests the circuit; it does not

test the detector’s sensing ability.

The TM121 test magnet is a strong magnet that can be
harmful to pacemaker wearers and to those with medical
implants.  Keep  the  magnet  away  from  magnetic media
such as credit cards and memory disks/chips.

COMPATIBLE CONTROL EQUIPMENT

Equipment Compatibility
Identifier

Installation/Wiring
Instructions

SZM (FS-250C System)

315-034850C

SXL-EX

315-095997

SZE-4X

315-096018

SZE-8AX

315-096022

PAD-5-CDC

A6V101030366

HZM

A6V10233195

HZM-Z

A6V11208370

CDC-4

A6V10239127

CZM-4

A6V10239188

CP-35

 315-084881

ZU-35

315-083222

TXR-320

A6V12013675

FDBZ492-R

A6V10336866

FDBZ492-PR

A6V10330327

FCC Statement

WARNING!

Installation and usage of equipment not in accordance with instructions manual may
result in:

Radiation of radio frequency energy

Interference to radio communications

 

Install and use equipment in accordance with installation instructions manual

 

Read the following information

AVERTISSEMENT!

L'installation et l'utilisation d'équipement non conforme au manuel d'instructions peuvent
entraîner :

Rayonnement d'énergie radiofréquence

Interférence aux communications radio

 

Installez et utilisez l'équipement conformément au manuel d'instructions d'installation

 

Lisez les informations suivantes

This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in
accordance with the instructions manual, may cause interference to radio communications.
It has been tested and found to comply with the limits for a Class A computing device pursuant to Part 15 of FCC
Rules, which are designed to provide reasonable protection against such interference when operated in a
commercial environment.
Operation of this equipment in a residential area is likely to cause interference in which case the user at his own
expense will be required to take whatever measures may be required to correct the interference.

30°

30°

30°

30°

Summary of Contents for OP121

Page 1: ... with STI Mechanical Protection Guard Model STI 9604 see www sti usa com for details Electrical Voltage 16 27 VDC Ripple 3 V peak to peak Supervisory Current 100 μA max Alarm Current 30 50 mA Start up Time 30 seconds max DO NOT install this detection device until all construction is completed DO NOT store this detection device where it can be contaminated by dirt dust or humidity DETECTOR PLACEMEN...

Page 2: ... The detector is marked DO NOT PAINT This is intended to prohibit painting during routine maintenance of the occupancy which can affect proper operation of the detector LED INDICATOR OPERATION The OP121 OH121 contains an LED indicator capable of flashing either one of three distinct colors green yellow or red The microprocessor based detector monitors the following Smoke in its sensing chamber Smo...

Page 3: ...mal 30 seconds per applied setting Open area Green 10 double flash Air duct Green 10 triple flash TESTING AND MAINTENANCE To assure proper operation of the detector and control panel it is required that both the Sensitivity test and the Functional test be conducted using the procedures outlined below SENSITIVITY TEST The OP121 OH121 monitors its smoke sensitivity automatically and requires no test...

Page 4: ...36866 FDBZ492 PR A6V10330327 FCC Statement WARNING Installation and usage of equipment not in accordance with instructions manual may result in Radiation of radio frequency energy Interference to radio communications Install and use equipment in accordance with installation instructions manual Read the following information AVERTISSEMENT L installation et l utilisation d équipement non conforme au...

Reviews: