Technical product information 

December 2009 

N 562/11 

Switching actuator, main module

 5WG1 

562-1AB11 

3x AC 230/400 V, 10 AX, C-load, load-check 

Siemens AG 

N 562/11, 6 pages 

Technical manual 

Industry Sector, Building Technologies 

Low Voltage Distribution 

© Siemens AG 2009 

Update: http://www.siemens.com/gamma 

P.O. Box 100953, D-93009 Regensburg 

Subject to change without further notice 

 

 

2.4.3.4/5 

General notes 

 

The operating instructions must be handed over to the 
client. 

 

A faulty device shall be sent with a Return Good Note 
for Service provided by the appropriate Siemens sales 
office to the following address: 
SIEMENS AG, Siemensstr. 10, D-93055 Regensburg 

 

If you have further questions concerning the product 
please contact our technical support: 

 

+49 (0) 180 50 50-222 
(0,14 €/min. from the German landline network, de-
viating mobile communications prices are possible) 

 

+49 (0) 180 50 50-223 
E-Mail: 

[email protected]

 

 www.siemens.com/automation/support-request 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for N 562/11

Page 1: ...r 30 seconds which of the modules A to E see figure 2 A5 was se lected last and the switching state of the corresponding outputs is indicated by the red LED integrated in buttons 1 to 3 see figure 2 A9 relay contact closed LED ON contact open LED OFF However if the button to switch on Direct mode is held down for at least 3 seconds then the yellow LED to indi cate Direct mode turns on permanently ...

Page 2: ...peed con trol conversion of a valve setting preset as a percentage into a pulse width modulated switching command thermal drive control a switching cycle and runtime totalization with threshold monitoring for each output and an integrated 8 bit scene control in which each output can be incorporated into up to 8 scenes To load the application program the Engineering Tool Software ETS is required as...

Page 3: ...ing between normal mode addressing mode 1 pushbutton for toggling between bus mode direct mode 2x 3 pushbuttons in 2 rows for direct operation toggling of 3 actuator outputs per row independent of the bus Display elements 1 red LED for checking the bus voltage and for display ing normal mode addressing mode 5 green LED for display of the selected module 1 yellow LED for displaying direct mode bus ...

Page 4: ... A4 Jack for connection of a switching actuator sub module A5 LED to indicate the selected device A6 Pushbutton to toggle between Bus Direct mode A7 LED to indicate Direct mode On A8 Pushbutton for direct operation of outputs 1 3 A9 LED to indicate whether the corresponding output is switched on or off A10 Without function A11 Without function A12 Screw type terminals of outputs 1 3 Installation a...

Page 5: ... notice 2 4 3 4 5 General notes The operating instructions must be handed over to the client A faulty device shall be sent with a Return Good Note for Service provided by the appropriate Siemens sales office to the following address SIEMENS AG Siemensstr 10 D 93055 Regensburg If you have further questions concerning the product please contact our technical support 49 0 180 50 50 222 0 14 min from ...

Page 6: ...62 1AB11 3x AC 230 400 V 10 AX C load load check Technical manual N 562 11 6 pages Siemens AG Industry Sector Building Technologies Update http www siemens com gamma Siemens AG 2009 Low Voltage Distribution Subject to change without further notice P O Box 100953 D 93009 Regensburg 2 4 3 4 6 Space for notes ...