Faults, causes and remedies
BA 2515
38
Operating Instructions, 10/2016, A5E38123453A/RS-AB
Faults
Causes
Remedy
Unusual noise from
the drive unit.
Drive unit bearing not lubricated
(motor size 160 and higher).
Regrease the bearing (Page 51).
Excessive bearing play and / or
bearing defective.
Check the bearing and replace if
necessary.
Fastening bolts loose.
Checking the tightness of fastening
Unusual motor
noise.
Excessive bearing play and / or
bearing defective.
Check the bearing and replace if
necessary.
Motor brake is rubbing.
Check air gap and adjust if necessary.
Inverter parameterization.
Correct the parameterization.
Oil escapes.
Incorrect oil level for the mounting
position being used.
Check the mounting position (Page 63)
and the oil level (Page 43).
Gearbox leaks.
Checking the gearbox for leaks
(Page 54).
Overpressure due to lack of venting. Mount the venting as appropriate for
the mounting position (Page 63).
Overpressure due to soiled venting. Clean the venting (Page 55).
Shaft sealing rings defective.
Replace the shaft sealing rings.
Cover / flange bolts loose.
Checking the tightness of fastening
bolts (Page 55). Continue to monitor
the gearbox.
Surface sealing defective (e.g. on
cover, flange).
Reseal.
Damage in transit (e.g. hairline
cracks).
Check the gearbox for damage in
transit.
Summary of Contents for MOTOX BA 2515
Page 1: ......
Page 2: ......
Page 8: ...Table of contents BA 2515 8 Operating Instructions 10 2016 A5E38123453A RS AB ...
Page 58: ...Disposal BA 2515 58 Operating Instructions 10 2016 A5E38123453A RS AB ...
Page 78: ...Declaration of Incorporation BA 2515 78 Operating Instructions 10 2016 A5E38123453A RS AB ...
Page 79: ......
Page 80: ......