Battery Charging
M35 series uses a Nickel Metal Hyride (NiMH) 500mAH battery pack as standard battery. It also
support the Lithium Ion 600mAH battery pack (For S35i phone) as optional battery for customer
want longer talk time.
PHOTO 2.3 M35i SERIES INSERTING BATTERY.
For M35, BATT+ has a voltage level from +3.0V to 5.5V, and a BATT_TEMP contact is used for
detecting abnormal increase in temperature of the battery.
If the temperature is too high or too low, there is a high probability
that the battery is not charged. To enable the charging process
again, battery and phone needs to cools down or warm up. Battery
replacement is not required.
A v o i d s h o r t i n g t h e b a t t e r y t e r m i n a l s .
Short Circuit Protection
For the Nickel Metal Hydride battery, a polyswitch in the battery pack protecting the battery from
short circuit and it should reset by itself after some time removing the short circuit.
For the Lithium Ion battery, it is short-circuit protected by an electronics fuse. The fuse will be
activated in case a too high current is drawn. This fuse will
not reset
automatically.
The resetting of the L-ion battery fuse can be done with either of the following procedures:
1. Insert the battery into the M35 and then connect the rapid charger to the phone. Wait for
approximately 10 second, then the mobile can be turned on again.
2. Plug the battery separately into the desktop charger. The fuse is reset immediately.
3. Insert the battery into the M35 and put the phone into the desktop charger. Wait for
approximately 10 second, then the mobile can be switched on.
Normal Charging
The battery can be charged when it is inserted into the phone. The charging process is
completely controlled by the mobile. Charging can be done with any of the following accessory:
1. Rapid charger
2. Travel charger
3. Car charger
4. Desktop charger