background image

5

Control panel variant 2

Control panel variant 3

Switching on the fan: variant 1

Press the On/Off button.
The fan setting can be increased with the 

@

 button or reduced 

with the 

 A

 button.

Intensive setting

You can use the intensive setting if there is a large build-up of 

odours and fumes/vapours.
Press the 

 button repeatedly until 

˜

 or 

 appears in the 

display.
The run time is limited. The fan is then automatically reduced to 

a lower fan setting. You can switch back manually at any time.

Switching on the fan: variants 2 and 3

Increase or reduce the fan settings by pressing buttons 1, 2 

or 3.

Intensive setting: variant 3

Press the 

˜

 button.

Lighting

The lighting can be switched on and off independently of the 

fan.

Installing and removing the filter

Risk of burns, risk of electric shock!

from appliance. Always leave appliance to cool down before 
cleaning or servicing. Switch off fuse or pull out mains plug.

Removing metal mesh grease filter

1.

Open the lock and fold down the metal mesh grease filter.
While doing this, place the other hand under the metal mesh 

grease filter.

2.

Take the metal mesh grease filter out of the holder.

With edge extraction

1.

Pull metal mesh grease filter downwards.
While doing this, place the other hand under the metal mesh 

grease filter.

2.

Take the metal mesh grease filter out of the holder.

Notes

Grease can accumulate in the bottom of the metal mesh 

grease filter.

Do not hold the metal mesh grease filter at an angle, 

otherwise grease will drip out.

Installing the metal mesh grease filter

1.

Insert the metal mesh grease filter.
While doing this, place the other hand under the metal mesh 

grease filter.

2.

Fold up the metal mesh grease filter, locking it in place.

/LJKW

2Q2II

)DQVHWWLQJV

3

/LJKW

2Q2II

)DQVHWWLQJV

,QWHQVLYH

VHWWLQJ

Summary of Contents for LC98BC540

Page 1: ... HQ QVWUXFWLRQV IRU LQVWDOODWLRQ DQG XVH WUDFWRU KRRG ...

Page 2: ...r is not liable for damage which is caused by improper use or incorrect operation Danger of suffocation from packaging material Never allow children to play with packaging material After unpacking the appliance check it for visible damage Do not connect the appliance if it has been damaged in transit These instructions apply to several appliance variants It is possible that individual features are...

Page 3: ...rve the specifications for your cooking appliance If gas and electric hobs are operated together the largest specified distance applies The width of the extractor hood must correspond at least with the width of the hob For the installation observe the currently valid building regulations and the regulations of the local electricity and gas suppliers Risk of electric shock from damaged connection c...

Page 4: ... air mode Note The exhaust air must not be conveyed into a functioning smoke or exhaust gas flue or into a shaft which is used to ventilate installation rooms which contain heating appliances Before conveying the exhaust air into a non functioning smoke or exhaust gas flue obtain the consent of the heating engineer responsible If the exhaust air is conveyed through the outer wall a telescopic wall...

Page 5: ...hock from appliance Always leave appliance to cool down before cleaning or servicing Switch off fuse or pull out mains plug Removing metal mesh grease filter 1 Open the lock and fold down the metal mesh grease filter While doing this place the other hand under the metal mesh grease filter 2 Take the metal mesh grease filter out of the holder With edge extraction 1 Pull metal mesh grease filter dow...

Page 6: ...e metal mesh grease filters can be cleaned in the dishwasher or by hand In the dishwasher Note If the metal mesh grease filters are cleaned in the dishwasher slight discolouration may occur This has no effect on the function of the metal mesh grease filters Do not clean heavily soiled metal mesh grease filters together with utensils Place the metal mesh grease filters loosely in the dishwasher The...

Page 7: ...lways be ensured An incoming exhaust air wall box alone will not ensure compliance with the limit Safe operation is possible only whenever the partial vacuum in the place where the firing equipment is installed does not exceed 4 Pa 0 04 mbar This can be achieved whenever the air needed for combustion is able to enter through openings that cannot be sealed for example in doors windows incoming exha...

Page 8: ...13 cm2 Flat ducts should have no sharp deflections Use sealing strip for deviating pipe diameters Checking the wall The wall must be level vertical and adequately load bearing The depth of the bore holes must be the same length as the screws The wall plugs must have a secure grip The enclosed screws and wall plugs are suitable for solid brickwork Suitable fasteners must be used for other structure...

Page 9: ...hen attaching the appliance ensure that it engages firmly with the brackets 3 Align the appliance horizontally by turning the brackets If required the appliance can be moved to the right or left Securing the appliance 1 Press the safety caps with the arrow upwards onto the brackets until they engage 2 Screw on the knurled nut and washer firmly Removing the safety caps If the safety caps must be re...

Page 10: ...ocket should be connected via its own circuit If the earthed socket is no longer accessible following installation of the appliance a disconnecter must be fitted as for a permanent connection If a permanent connection is required the installation must feature an all pole disconnecter circuit breakers fuses and contactors with a min 3 mm contact opening The permanent connection may be installed by ...

Page 11: ...11 ...

Page 12: ...Siemens Electrogeräte GmbH Carl Wery Straße 34 81739 München Germany 9000548221 9000548221 930903 ...