Page EN-2
SITRANS LR 300 – QUICK START MANUAL
7ML19985QA82
mmmmm
English
Specifications
Ambient/Operating Temperature
Power
• 24-230 V ac, +15%, 40-70Hz, 28 VA (11W) or 24-230 V dc, +15%, (9W)
Approvals (verify against device nameplate)
•
General:
CSA
US/C
, FM, CE, 3A Sanitary
•
Radio:
Europe, Industry Canada, FCC
•
Hazardous:
Europe;
EEx de IIC T6
ATEX II 1/2G, EEx de IIT6 or EEx d IIC T6
U.S.;
Class I, Div. 1, Gr. A,B,C,D (Class I, Zone 1, IIC T6)
Class II, Div. 1, Gr. E,F,G
Class III
Canada;
Class I, Div. 1, Gr. A,B,C,D (Class I, Zone 1, IIC T6)
Class II, Div. 1, Gr. E,F,G
Class III
•
Lloyds Register of Shipping, categories ENV1, ENV2, ENV3, ENV5
Installation
WARNING: Internal temperature must not exceed 81
o
C! Warranty may be void.
Notes:
•
This instrument features a universal power supply. Either ac or dc voltage may be
applied to the same terminals.
•
The equipment must be protected by a 15 A fuse or circuit breaker in the building
installation.
•
The circuit breaker or switch in the building installation, marked as the disconnect
switch, shall be in close proximity to the equipment and within easy reach of the
operator.
Notes:
•
The SITRANS LR 300 is to be used only in the manner outlined in this manual, otherwise
protection provided by the equipment may be impaired.
•
Installation shall only be performed by qualified personnel and in accordance with local
governing regulations.
•
This product is susceptible to electrostatic shock. Follow proper grounding procedures.
•
Do not use a Ground Fault Interrupt (G.F.I.) with the SITRANS LR 300. The ground path is
used for filtering purposes in conjunction with the universal power supply.
•
The use of Teflon tape or other appropriate sealant may be used to aid in sealing tapered
threaded connections for use in pressure applications.
internal enclosure temperature (P343)
max. 81
o
C
process temperature
ambient temperature
(surrounding enclosure volume)
flange temperature
wrench (to open
enclosure)
Summary of Contents for IQ RADAR 300