background image

6/8

 

2 3 4  

0

1  

Motor direction:  1: CCW    0: CW 

2 4 0  

0

9999 1000 

The ratio between motor and machine (1000 stands for 1:1) 

2 4 2  

0

359 0 

Up needle stop angle (After detecting the synchronizer signal) 

2 4 3  

0

359 175 

Down needle stop angle 

2 4 4  

0~800 200 

Running delay time when presser footer comes down (ms) 

2 4 7  

0

2000 

Oil refill time alarm (hour. 0: function deactivated) 

2 4 8  

0

4000 

Oil alarm, stop operation time (hour. 0: function deactivated) 

2 7 4  

1

500 

70 

No.2 electromagnet fully output time ms 

2 7 5  

1

100 

No.2 electromagnet chopping on time ms(Reserved) 

2 7 6  

1

100 

No.2 electromagnet chopping off time ms(Reserved) 

2 7 8  

1

500 

150 

No.3 electromagnet fully output time ms 

2 7 9  

1

100 

No.3 electromagnet chopping on time ms(Reserved) 

2 7 A  

1

100 

No.3 electromagnet chopping off time ms(Reserved) 

3.3 Monitor mode 

1. Pressing 

P

+

 

 

key to enter monitor mode.   

2. Press 

and

key to adjust the parameter number, press 

 

key

 

and the para value is shown at the same 

time.  

3. Press 

 

key then return to normal sewing mode. 

No. Description 

No. 

Description 

0 1 0  

Counter for stitches 

0 2 4  

Machine angle 

0 1 1  

Counter for sewing pieces 

0 2 5  

The sampling voltage of pedal

 

0 1 3  

State of encoder

 

0 2 6  

The ratio between motor and machine

 

0 2 0  

DC voltage

 

0 2 7  

The total used time(hours) of motor

 

0 2 1  

Machine speed 

0 2 8  

The sampling voltage of interaction

 

0 2 2  

The phase current   

0 2 9  

Software version   

0 2 3  

Initial electrical angle 

0 3 0 - 0 3 7  

The history record of error codes 

3.3 The Warning Message  

Alarm code 

Description

 

Corrective

 

A-1 

Fuel filling warning 

Fuel filling. Press P key to clear. 

A-2

 

Count over for stitches 

The counter reaches the limit. Press P key to reset the counter. 

A-3

 

Count over for sewing 

pieces 

The counter reaches the limit. Press P key to reset the counter.

 

A-4

 

Emergency stop 

Press the key of emergency stop to clear.   

A-5

 

Lift needle locking 

Then press the needle lifting locking button, can eliminate the 

needle lifting locking state. 

 

Power is off 

Please wait for 30 seconds, then turn on the power switch. 

 

Safety switch alarm 

Adjust the machine to the correct position. 

Summary of Contents for HMI-15

Page 1: ... use the controller For installing and operating the controller properly and safely qualified personnel are required Please try to stay away from arc welding equipment in order to avoid electromagnetic interference and malfunction of the controller Keep in room bellow 45 and above 0 Do not humidity below 30 or above 95 or dew and mist of places Install the control box and other components turn off...

Page 2: ... Icon Description Index Icon Description Automatic trimming four constant stitch sewing Presser foot lifting after trimming One shot sewing Presser foot lifting at seam end Position up Start back tacking Soft start End back tacking Thread clamp W sewing Number display Free sewing Sewing segments index Multi section constant stitch sewing 2 2 Key Functions Key Name Description Parameter setting key...

Page 3: ...ycle only lifting at machine stop only lifting at machine stop and after trimming cycle both Trimming cycle selection Enable or disable the trimming cycle Start back tacking setting key Switch during all start tacking type when pressing No tacking once tacking double tacking 4 repeat tacking Tacking stitches A B can be set using the key and the key End back tacking setting key Switch during all en...

Page 4: ... 70 20 Stitch balance for start back tacking No 1 1 1 5 1 70 24 Stitch balance for end back tacking No 3 1 1 6 1 70 20 Stitch balance for end back tacking No 4 1 3 0 0 1 2 3 2 Speed curve adjustments 0 ramp curve 1 polygonal curve 2 quadric curve 3 S type curve 1 3 1 200 4000 3000 The turning point speed of two segment curve 1 3 2 0 1024 800 The turning point sampling voltage of the pedal when two...

Page 5: ...operation panel 1 6 2 1 2 Restore factory setting 1 6 3 1 2 Save current parameters as user defined default parameters 1 6 4 Password 2 0 3 5 359 10 Trimming output start angle TS down needle position angle as the reference point 2 0 4 10 359 120 Trimming output end angle TE Down needle position angle is the reference and this value should be bigger than TS 2 0 A 10 60 20 Motor torque improvement ...

Page 6: ...shown at the same time 3 Press key then return to normal sewing mode No Description No Description 0 1 0 Counter for stitches 0 2 4 Machine angle 0 1 1 Counter for sewing pieces 0 2 5 The sampling voltage of pedal 0 1 3 State of encoder 0 2 6 The ratio between motor and machine 0 2 0 DC voltage 0 2 7 The total used time hours of motor 0 2 1 Machine speed 0 2 8 The sampling voltage of interaction 0...

Page 7: ...t in the sewing machine Replace encoder Replace sewing motor E r 0 9 Brake circuit failure Check the brake resistor plug on the electric board Replace the control box E r 1 0 Communication failure Check the connection and if necessary plug in Replace the control box E r 11 Machine head needle positioning failure Check if the connection line between machine head synchronizer and controller is loose...

Page 8: ...actory Setting is recovered displaying as left LCD 3 8888 When the LCD is displayed as 8888888 the recovery is accomplished The machine is recovered back to the initial state in delivery 4 3 Pedal Sensitivity Adjustment Pedal starts moving from the initial position p 136 where the motor stops slowing forward to the low speed point p 137 where the motor run as the minimum speed p 100 continuing to ...

Reviews: