Feature
X 76200 Y
Option
Pause after signal-key
1
-
2 1 = 800 ms
2 = 1600 ms
3 = 3200 ms
Automatic attenuation correction
(dependant on country)
1
-
3 0 = off
1 = on
Time for end of call identification
(to distinguish between 2 ringing pulses of
one call with long pauses between pulses
and 2 separate calls)
1
-
4 0 = 4 sec.
1 = 5.5 sec.
2 = 7 sec.
3 = 11 sec.
Hook-flash-prevention (cradle switch
identification) (short press on cradle switch-
key is extended by SW to prevent that it is
interpreted as a press on the flash-key)
1
-
5 0 = 800 ms
1 = 2000 ms
Pause after line seizure
1
-
6 1 = 1 sec.
2 = 3 sec.
3 = 7 sec.
4 = 2.5 sec.
System PIN reset
3 76200 -
-
Programming data on an address
4 76200 1 Specific code needed
Read out SW-version
4 76200 2 Example: 01002_…..
01 = SW-variant
002 = SW-version
Range of ringing frequency recognition
4 76200 3 0 = 23- 54 Hz
1 = 20- 60 Hz
2 = 15-75 Hz
Dial pulsing: pulse pause ratio
4 76200 4 0 = 1.5 : 1
1 = 2 : 1
CLIP activation
4 76200 5 Select 0 (on) or 1 (off)
Off-hook CLIP activation
4 76200 6 Select 0 (on) or 1 (off)
Approval test
6 76200 6
-
Gigaset 4015 Micro (country specific (e.g. Switzerland)):
Feature
X 76200 Y
Option
Select speech 1 for AM phrases (tones)
2
-
1
-
Select speech 2 for AM phrases
2
-
2
-
Select speech 3 for AM phrases
2
-
3
-
Select speech 4 for AM phrases
2
-
4
-