11
Electrical
connection
Prior to connection check the voltage and total
output on the technical label affixed to the appliance.
It is obligatory that this appliance be earthed.
When connecting the appliance, ensure the earth
wire is connected first and that all wires are
connected to the correct terminals.
If a direct connection to the mains is required, it is
necessary to install a device that ensures an omni-
polar disconnection from the mains, with an
opening distance of the contacts such as to ensure
the complete disconnection in the conditions
foreseen by the category of overvoltage III, as per
the installation’s regulation.
This is not the case if the connection is by means of
a plug, provided the user has easy access to the
plug itself.
Fuse rating: 3 Amp.
When connecting the appliance please ensure that
the earthing wire is properly connected. In the event
of an accident due to the fact that the appliance is
not earthed, or that the earthing is faulty, we do not
accept any form of responsibility.
The type of cable connecting the appliance to the
electricity supply must be H05RR-F3 G 0.75.
In the event that the connecting cable must be
replaced due to damage only this type of cable
should be used. This should only be carried out by
one of our after-sales service technicians.
CE: This appliance complies with the following EU
directives:
- 72/23/EEC
- Low Voltage Directive
- 89/336/EEC - EMC Directive
- 90/396/EEC - Directive on Gas Appliances
Summary of Contents for ER12553EU
Page 1: ...1 Operating installation and caring instructions ER59553EU ...
Page 7: ...7 Dimensions in mm approx 60 ...
Page 10: ...10 Picture 3 ...