background image

3

Installation

Statutory requirements

This installation must conform with the following:

Manufacturer’s Installation instructions

Local Gas Fitting Regulations

Municipal Building Codes

Refer to AS/NZS 5601.1 for Gas Installations

S.A.A. Wiring Code

Local Electrical Regulations

Any other statutory regulations

Preparing to install

Refer to AS/NZS 5601.1 for piping size details. These built-in 

cooktops are intended to be inserted in a benchtop cutout.
Only an officially authorised technician should connect the 

appliance.
Before you begin, turn off the gas and electricity supply.

Before connecting the unit, check whether the local connection 

conditions (type of gas) are compatible with the unit’s setting. 

Observe any special conditions imposed by local suppliers 

(utilities). The specifications of this cooktop are stated on the 

data label located on the bottom of the cooktop base.
A duplicate data label is supplied for adhesion to an accessible 

location near the hotplate if the data label on the base of the 

hotplate cannot be accessed when the hotplate is installed.

Clearances

A range hood fitted above the top must be installed according 

to the installation instructions for the range hood. A minimum 

distance of 650 mm is required for a range hood and 750 mm 

for an exhaust fan.
Any adjoining wall surface situated within 200 mm from the 

edge of any hob burner must be a suitable non-combustible 

material for a height of 150 mm for the entire length of the hob. 

Any combustible construction above the hotplate must be at 

least 650 mm above the top of the burner and no construction 

shall be within 450 mm above the top of the burner.

PLQ

PLQ

Summary of Contents for EC945RB91A

Page 1: ...86 5 16758 7 216 167 7 21 16758 7 216 0 17 1 1 16758 7 216 7KLV FRRNWRS LV IRU XVH ZLWK 1DWXUDO DV DQG 8QLYHUVDO 3 HDYH WKHVH LQVWUXFWLRQV ZLWK WKH RZQHU 5 GMK10047 ...

Page 2: ...minimum clearance of 650 mm 24 The gas pressure regulator supplied with the appliance must be installed in line with the gas pipe N G only For pressure testing in excess of 3 5 kPa 1 2 psig the appliance and its individual shutoff valve must be disconnected from the gas supply piping system Important When using a very large pot leave a gap of at least 50 mm 2 to avoid damaging any parts in bench t...

Page 3: ...al conditions imposed by local suppliers utilities The specifications of this cooktop are stated on the data label located on the bottom of the cooktop base A duplicate data label is supplied for adhesion to an accessible location near the hotplate if the data label on the base of the hotplate cannot be accessed when the hotplate is installed Clearances A range hood fitted above the top must be in...

Page 4: ...iance is connected to the mains 240 VAC by means of the connecting lead which must be fixed to the kitchen unit to prevent it from coming into contact with hot parts of the cooktop or an oven installed underneath and remain accessible after installation of the cooktop When making this connection make sure that the lead cannot come into contact with hot parts of the cooktop This appliance must be e...

Page 5: ...low for sizes Before conversion the cooktop must be disconnected from the electricity and gas valves must be turned to the OFF position Changing the nozzles of the burners on the cooktop 1 Remove the pan supports burner covers and diffusers 2 Change the nozzles using the spanner provided by our Service Centre code 340847 for double and triple flame burners code 340808 taking special care to ensure...

Page 6: ...W Rapid burner up to 3 kW Dual double flame wok burner up to 5 kW Accessories Depending on the model the hob may include the following accessories These can also be acquired from the Technical Assistance Service The manufacturer accepts no liability if these accessories are not used or are used incorrectly 5 2 1 Additional wok pan support Only for use on wok burners with pans with a round base Usi...

Page 7: ...er and outer flames can be controlled separately The available power levels are as follows Warnings It is normal to hear a soft whistling noise while the burner is operating When first used it is normal for the burner to give off odours This does not pose any risk and does not indicate a malfunction They will disappear in time An orange coloured flame is normal This is caused by the presence of du...

Page 8: ... leave acidic liquids e g lemon juice vinegar etc on the hob Burner Very high High Medium Low Wok burner Boiling steam ing griddling toasting paellas Asian food wok Reheating and keeping things hot cooked and pre cooked dishes Rapid burner Escalopes steaks ome lettes frying Rice white sauce ragout Steaming fish vegeta bles Semi rapid burner Steamed pota toes fresh vege tables vegetable stews pasta...

Page 9: ... or circuit breaker has tripped The automatic switching on function does not work There may be food or cleaning products stuck between the ignition sparkers and the burners The space between the ignition sparker and the burner must be clean The burners are wet Dry the burner caps carefully The burner caps are not correctly positioned Check that the burner caps are correctly posi tioned The applian...

Page 10: ...10 Wiring diagram A Switch B Blue wire C Brown wire D Terminal E Ignition module ...

Page 11: ...BSH Hausgeräte GmbH Carl Wery Straße 34 81739 München GERMANY 9000803399 9000803399 E Manufactured by BSH Hausgeräte GmbH under Trademark License of Siemens AG ...

Reviews: