Camera settings
26
Siemens AG
04.2011
9.3.9
CAMSET
<CAMSET MENU>
CAM ID
BAUD RATE
PROTOCOL
DISP MODE
DISP ITEM
TITLE
ALARM TEXT
SAVE
END
CAM ID
Camera ID: 1 – 255
BAUD RATE
Serial communication speed: 2400/4800/9600/19200 BPS
PROTOCOL
Operating protocol:
z
COMMAND: for factory use only
z
SIEMENS – B (Parity bit = Even)
z
SIEMENS – S (Parity bit = Even)
z
MOLYNX (Parity bit = Even)
z
PELCO – D (Parity bit = None)
z
PELCO – P (Parity bit = None)
DISP MODE
OSD print mode: Off/Push, On/On
DISP ITEM
Display elements:
1: Camera title and camera number
2: Camera title, zoom ratio and camera number
TITLE
Press ENTER to configure camera name
ALARM TEXT
Press ENTER to configure alarm text
SAVE
Press ENTER to save CAMSET configuration
END
Back to the next higher menu level
Move the cursor using the "Far/Near", "Tele/Wide" keys.
Press the MENU key to open a sub-menu.
TITLE TEXT
<TITLE MENU>
A B C D E F G H I J
K L M N O P Q R S T
U V W X Y Z 0 1 2 3
4 5 6 7 8 9 ( ) :
; . -
! < > ,
`
CMD
< > S E
CMD description
←
: One position to the left
→
: One position to the right
< : Deletes character at cursor position and
moves to the left
> : Deletes character at cursor position and
moves to the right
S : Save the present setting
E : Exit
If you make any changes in the
BPS
or
PROTOCOL
submenus, be sure to select
SAVE
PROTOCOL
& BPS
to save your changes.
Do not disconnect the camera from the power source while saving.