Installing the
Camera
23
Siemens Building Technologies
Fire Safety & Security Products
03. 2005
7.2.15 REMOTE
Fig. 18
REMOTE
This function is for setting the remote control menu
Move the cursor to the position as shown in Fig. 18.
Use the ENTER button to enter the submenu.
7.2.15.1 MODEL
MODEL indicates the camera model.
7.2.15.2 ADDRESS
When multiple cameras are used via RS-485, for example, each camera must
have its own specific address.
Use ADDRESS to set the camera address in a range of 1-255.
The camera address must be set correctly before installing the camera. Otherwise
remote access may not be possible.
7.2.15.3 BAUD RATE
This function is used to set the camera’s remote baud rate in the range from 2400
to 19200 bits per second.
REMOTE MENU
MODEL CCBS1337-LP
ADDRESS 001 ~ 099
BAUD RATE 2400
PROTOCOL SIEMENS-U
SOFT VER. X.2.2
PATTERN OFF
SAVE DEFAULT
WHITE BAL ATW2
GAMMA 0.45
APERTURE MID
MIRROR OFF
PRIVACY ZONE <OFF>
OPTION <SET>
REMOTE <SET>
BACK EXIT CANCEL DEFAULT