Installing the
Camera
13
Siemens Building Technologies
Fire Safety & Security Products
03. 2005
7
Installing the Camera
7.1
Installation
1.
Connect the BNC cable to the video output
⑥
2.
Connect the power source to the power terminal
Caution:
If using a DC supply, make sure the polarity is correct. Incorrect connection may cause malfunction
and/or damage to the camera.
3.
To reduce radiation sufficiently, please wind one turn around the core, see figure
below
Location
Core illustration
for what camera
Power cable
LP
Y/C cable
LP / MP
EIM-0050751G
4.
Adjust the back focus
The back focus is factory-adjusted before delivery for a CS mount lens. If re-
adjustment is necessary, please loosen screw
②
, set the camera to AES mode
(see section 7.2.14.2: BACK FOCUS), then rotate the back focus wheel
①
until a
sharp image appears. Tighten screw
②
.
7.2
Function Settings
Select ENTER on the OSD; the menu will appear on the display and will disappear
after 30 seconds if no action occurs. The shaded setting area means an item is
selected; it keeps blinking.