Installing the
Camera
22
Siemens Building Technologies
Fire Safety & Security Products
03.2005
OFF
The alarm input function on the rear panel is disabled.
ON
The alarm input function on the rear panel is enabled. When an alarm occurs, the status of
alarm output will change, i.e. from NO to NC or from NC to NO, depending on the setting
of ALARM OUT.
Use the OSD navigation keys to define the optional alarm text to be displayed in
case of an alarm.
7.2.14.4 ALARM OUT
This function sets the initial status of the ALARM output relay.
NO:
normally open
NC:
normally closed
7.2.14.5 ALARM DELAY
Use the LEFT/ RIGHT button to select 30, 60, 90, 120 seconds for the timing delay
of ALARM operation
7.2.14.6 ALARM TEXT
Use ENTER to access the submenu. When the alarm input is active, the text will
be shown on the display.
7.2.14.7 CHROMA
Use the LEFT/ RIGHT button to select a value from 1 to 9.
7.2.14.8 CAMERA TEXT
Fig. 17
CAMERA TEXT
Use ENTER to access the submenu. When you leave the OSD menu, the text will
be shown on the display.
You can position the text anywhere on the screen.
CAMERA TEXT MENU
TEXT IP <SET>
TEXT ****************
A B C D E F G H I J K L M
N O P Q R S T U V W X Y Z
0 1 2 3 4 5 6 7 8 9 : < >
□
- . , ; x /
BACK CLEAR