Transponders / ID cards
8
Transponders / ID cards
The configuration settings offer users numerous options for reading ID card data in
different formats and for the transfer of data to the reader using the existing
interface.
The procedure to determine the required configuration parameters can be carried
out based on the following order of events.
Which 13.56 MHz transponder ?
(Card technology)
ISO14443A
Part 1 – 3 UID + Block
Mifare 1k
Mifare 4k
Mifare UltraLight
my-D proximity
(SLE55Rxx)
ISB
Part 1 – 3 UID only
my-C SLE66CL160S
ISO15693
Part 1 – 3 UID only
my-D vicinity (SRF55VxxP, SRF55VxxS)
I-code SLI
Tag-IT HFI
LRI512 (STM)
▼
What is to be read ?
Serial number
Data from block (direct)
Data from sector/block (direct)
Data from block via MAD (direct)
▼
Where are the data located ?
Data in block x starting at y
Data in block z via MAD addressed with AID
▼
What is the data format ?
Binary
BCD (4-bit, half byte)
ASCII (7-bit)
Wiegand format
▼
Which reader interface ?
RS485
CerPass reader protocol
UCI reader protocol
Clock / Data
Wiegand (D0, D1)
5-bit ABA (clk, data, cls) - Magstripe Track II
▼
Data output format
What is where in the output data string
Data format:
5-bit ABA
7-bit ASCII
Wiegand
Without / with PIN
Detailed knowledge about the content to be read and the format, as well as a
possibly existing access protection, on the ID card is required.
18
Siemens Building Technologies
Fire & Security Products
12.2004
Summary of Contents for AR6181-MX