background image

GAMMA

instabus

Technical Product-Information

August 2017

Control Module Box AP 118

5WG1 118-4AB01

Siemens AG

AP 118, page 3 / 6

Technical Manual

Infrastructure and Cities Sector, Building Technologies
Control Products and Systems

© Siemens AG 2017

Update: http://www.siemens.com/gamma

P. O. Box 10 09 53, D-93009 Regensburg

Subject to change without further notice.

2.4.2.11/3

A1

Product label

A2

Hole for screw fastening of Control Module Box

A3

Screws for securing the lid

A4

Latching clamp for locking the lid

A5

Control Module Box, Lid

A6

Hinge for lid

A7

Bushing for BUS cables (with strain relief)

A8

Bushing for low voltage cables (with strain relief)

A9

Control Module Box, base

A10

Bus terminal

A11

Mounting location for one RS / RL module

A12

RS module (to be ordered separately)

A13

RL module (to be ordered separately)

A14

Clamp for strain relief (cut off from base)

A2

A14

A7

A6

A11

A9

A4

A2

A14

A8

figure 2b: Mounting

Removing the lid of the Control Module Box:

- Remove the screws (A3) securing the lid.
- Pull the latching clamp (A4) away from the lid (A5), lift

the lid up, swivel it up and remove it from the hinge
(A6).

Mounting the lid of the Control Module Box:

- Hook the lid (A5) into the hinge (A6).
- Push the lid (A5) down until it audibly snaps into the

latching clamp (A4).

- Fasten the screws (A3) to secure the lid.

A10

figure 3: Removing/Mounting the lid of the Control

Module Box

Mounting / Dismounting of RS /RL modules:

A  RS  module  (A13)  or  an  RL  module  (A14)  may  be  in-
stalled at the mounting location (A12) of the Control
Module  Box.  Mounting  of  the  RS  and  RL  modules  is  de-
scribed generically in these mounting and operating
instructions.
Notes on wiring and commissioning of specific modules
may be found in the respective documentation for that
module.

A1

A12

A10

A14 A7

A13

A9

A14

A8

figure 4: mounting / dismounting of RS/RL modules

Summary of Contents for AP 118

Page 1: ...tuator 2 x 6A 5WG1 525 2AB23 Universal dimmer 1 x 250VA The mounted module is connected to the bus line via a bus terminal block The AP 118 Control Module Box provides wiring space with room for two connectors for PE and N conductors This allows for secure connection of the PE and N con ductors of the cables inserted into the AP 118 Control Module Box For strain relief cables can be secured at the...

Page 2: ... category according to IEC 60664 1 III Bus safety extra low voltage SELV DC 24 V Environmental specifications Climatic withstand capability EN 50090 2 2 Ambient temperature operating 5 45 C Ambient temperature non op 25 70 C relative humidity non condensing 5 bis 93 CE norm complies with low voltage regulations Mounting and Connecting General description The Control Module Box is designed for on s...

Page 3: ...separately A14 Clamp for strain relief cut off from base A2 A14 A7 A6 A11 A9 A4 A2 A14 A8 figure 2b Mounting Removing the lid of the Control Module Box Remove the screws A3 securing the lid Pull the latching clamp A4 away from the lid A5 lift the lid up swivel it up and remove it from the hinge A6 Mounting the lid of the Control Module Box Hook the lid A5 into the hinge A6 Push the lid A5 down unt...

Page 4: ... with 0 6 0 8 mm Ø B13 Hinge joint for mounting hinge of the RL module B14 Terminals Mounting of a RS module AP 118 Remove the lid of the Control Module Box Insert the bus connection module B5 in such a way into the insertion point B6 for the bus connection module that the bus connection pins B10 point to the insertion point for the bus terminal B11 Press the bus connection module B5 down until it...

Page 5: ...he bus terminal B12 To remove the RL module B2 insert a screw driver between the module and the mounting location on the bus terminal side and push it up to release it from the snap in hooks Swivel the RL module B2 up pull it down out of the hinge B13 and remove it from the mounting location B4 Mount the lid again figure 8 dismounting an RL module Wiring Slipping off on bus connection blocks The b...

Page 6: ...uits are connected via screwless plug in terminals E1 Remove approx 9 10 mm of insulation from the wire E 1 1 and plug it into the terminal E1 The terminals are designed for connection of two wires allowing to loop through the terminal block Note The maximum permissible terminal load current is 16A Remove wires Press the terminal interlocking of the terminal F1 with a screw driver and remove the w...