CI1142 in housing H47...
36
Building Technologies
008725_h_en_--
Fire Safety & Security Products
06.2011
mains
Basic equipment
Option
B3Q321
B2F020
Battery
FA...
I-Bus
FBF FSK
HM
E3L030
1..2
E3G070
Z3B171
1........7
CI1142
E3G...
E3L...
E3M...
B3R051
C-Bus
250VAC 10A
24V
E3C011
24V
5V
24V
RT
24V
AlgoPilot
B3Q...
1
2
E3I020
RS232
K3I090
PSA/Pager
or
Printer
RT = Remote transmission
internal or
external printer
LON-Bus
K3I050
B3Q580/
B3Q59x
E3I040
K3I110
LON synoptic converter
LON I/O card
Floor indicator terminal
CT1142
(additional operating facilities)
Fire control
installation
VdS peripheral
equipment
H47G611 components
Control and operating unit
B3Q...
AlgoPilot operating console
All AlgoPilot variants –> see page 47
H26T...
Plexi glass doors for AlgoPilot B3Q...
Option –> see page 48
Z5B...
Labeling kit
Depending on language –> see page 50
E3G070
5466610001
'Universal' control plug-in module
For alarm devices and control outputs
Line plug-in modules
Depending on detector series
For details of line plug-in modules –> see page 63
LON plug-in module
For details of floor repeater display –> see page 78
Control plug-in modules
If more than 7 programmable control
outputs are needed
For details of control plug-in modules –> see page 72
Interfaces
If there is space to fit
E3H021
A5Q00024660 'CERLOOP' gateway
Double Euroboard (2 plug-in slots) –> see page 82
E3I020
4602390001
RS232 plug-in module
For connecting B2Q191 printer or external printer
K3I090
5108200001
PSA interface board
For connecting PSA/pager and internal/external printer
Power supply
For calculating the emergency power operation duration, see page 99
B2F020
A5Q00025281 Converter 115/230 V AC ->29.6 V DC, 6
A
B1F120
4952330001
Converter 115/230 V AC ->24 V DC, 3 A
Generally for supplying fire controls
B2F060
5112850001
Converter 115/230 V AC ->24 V DC, 4.5
A
E3C011
5054790001
Plug-in battery charging module
FA2006-A1
A5Q00019356 12 V/24 Ah battery
FA2007-A1
A5Q00022897 12 V/38 Ah battery
Z3I450
4842730001
'CH' mains socket
Z3I1040
A5Q00004129 'CH' remote transmission kit
Z3I041
4962900001
Surge arrester kit
Option
Housing/options
H47G611
4953850001
'Doors with cut-out' housing kit
For details of housing –> see page 58
H23B010
4762100001
Cover
Rather than H23B040 or B3Q321 or B3R051
H23B040
4845900001
Information module
Brief operating instructions
B3Q321
5656840001
'CH' fire brigade operating unit
CH only
B3R051
4905130001
'2x24 displays' parallel display
Option
Z3I510
4848460001
Cable set for H47... / CI11...
Compulsory
Z3I380
4755670001
I bus flat cable + 'long' supply cable
Needed for connection between levels
Z1I020
4754990001
9-wire connection cable with board hol-
der, 0.5 m
For internal advance wiring
Z1I030
4755090001
19-wire connection cable with board
holder, 0.5 m
For internal advance wiring
Z1I060
5258020001
4-wire connection cable with board hol-
der, 0.5m
For internal advance wiring
Z1I100
A5Q00007486 10-wire connection cable with board
holder, 0.5 m
For internal advance wiring
Z3B171
4843830001
1 x 250 V AC/10 A relay module
Intermediate relay for fire controls (max.8)
Z3I330
4751560001
Terminal block, 2x20 terminals
3 items are supplied with H47G611
Z3I420
4838180001
Back-up terminal block
For extra back-up terminals
Z3G220 5258440001
Marine
kit
Z3G240
5329500001
Kit for increased vibrations