Functional Information
3TK2845 Multifunction Device Manual
GWA 4NEB 926 2087-22 DS 01
2-5
Legend
Sensor interface
Safety logic
Parameters
S
x
Sensor input
CAS/OS
Cascading input or operational switching (operational switching:
connection of, for example, a PLC output. Three enabling circuits
and the connected consumers can then be switched via the
machine controls. The safety function is higher-level).
Key-
operated
switch
3TK2845-.HB.. : Bridging of the sensor connected to S2 (standard
operation/maintenance)
3TK2845-.DB.. : Bridging of the sensor connected to S2 (standard
operation/maintenance)
3TK2845-.EB.. : Bridging of the protective door function and
activation of the enabling button
3TK2845-.FB.. : Enabling of the protective door
3TK2845-.GB.. : Enabling of the protective door
AS
Automatic start-up: Device starts automatically after the enabling
conditions have been fulfilled. A manual start-up is possible when
a START button is integrated in the feedback circuit (up to
Category 3 according to EN 954-1).
MS
Monitored start-up: The device only starts after the enabling
conditions have been fulfilled and a start signal has been issued.
AS/MS
Automatic or monitored start-up, depending on the
parameterization
Switch-off delay
Switch-on delay
AS/MS
Automatic or monitored start-up, depending on the device type/
parameterization
CC
with/without cross-circuit monitoring
td
td
Summary of Contents for 3TK2845
Page 6: ...3TK2845 Multifunction Device Manual iv GWA 4NEB 926 2087 22 DS 01 ...
Page 38: ...Functional Information 3TK2845 Multifunction Device Manual 2 26 GWA 4NEB 926 2087 22 DS 01 ...
Page 44: ...Technical Data 3TK2845 Multifunction Device Manual 3 6 GWA 4NEB 926 2087 22 DS 01 ...
Page 66: ...3TK2845 Multifunction Device Manual 5 16 GWA 4NEB 926 2087 22 DS 01 ...
Page 68: ...3TK2845 Multifunction Device Manual GWA 4NEB 926 2087 22 DS 01 ...