Transport, assembly, and connection
3.3 Electrical connection
A5E00264365A
40
Siemens AG Operating Instructions 2.02 1PL622
NOTICE
Do not turn the Sensor Module with a pipe wrench or hammer or any similar tool as this
could damage the Sensor Module.
Turn the Sensor Module by hand.
Typical twisting moment:
4 ... 8 Nm
S
¡
ແ
Figure 3-11 Sensor Module ① mounted on terminal box
NOTICE
Changing the cable outlet direction by any improper means will cause damage to the
connecting cables.
The permissible rotation range must not be exceeded. A maximum of ten changes to the
rotation angle of the Sensor Module are permissible within the rotation range.
[ID 964]
3.3.8
Connecting the temperature sensor
Connection
Connect the wires of the temperature sensor to the speed sensor connector with the aid of
connecting leads (see section entitled "Connecting the speed sensor").