Assembly
5
When carrying out any work on the machine, observe the general safety instructions
(Page 15) and the specifications contained in EN 50110‑1 regarding safe operation on
electrical equipment.
Note
Loss of conformity with European directives
In the delivery state, the machine corresponds to the requirements of the European directives.
Unauthorized changes or modifications to the machine lead to the loss of conformity with
European directives and the loss of warranty.
WARNING
Explosion hazard when making modifications to the machine
Substantial modifications to the machine are not permitted – or may only be performed by
the manufacturer. Otherwise an explosion can occur in an explosive atmosphere. This can
result in death, serious injury or material damage.
Please contact the Service Center, if necessary.
5.1
Preparations for installation
5.1.1
Requirements for installation
The following requirements must be satisfied prior to starting installation work:
● Staff have access to the operating and installation instructions.
● The machine is unpacked and ready for mounting at the installation location.
Note
Measure the insulation resistance of the winding before starting installation work
Wherever possible, measure the insulation resistance of the winding before starting
installation work. If the insulation resistance lies below the specified value, take
appropriate remedial measures. These remedial measures may necessitate the machine
being removed again and transported.
SIMOTICS TN Series N-compact 1LA8
Operating Instructions 05/2014
43
Summary of Contents for 1LA8
Page 2: ...23 05 2014 10 18 V8 00 ...
Page 12: ...Table of contents SIMOTICS TN Series N compact 1LA8 12 Operating Instructions 05 2014 ...
Page 100: ...Operation 8 11 faults SIMOTICS TN Series N compact 1LA8 100 Operating Instructions 05 2014 ...
Page 173: ...AC Declaration of conformity 1LA8 area 22 AA KE NSR _1LA8_1PQ8_1PP8_1LP8 ...