The motors should be stored indoors in dry, low-dust and low-vibration (v
eff
< 0,2 mm/s)
rooms. The motors should not be stored longer than two years at room temperature
(+5 °C to +40 °C) (41 °F to 104 °F) to retain the service life of the grease.
4.2
Installation
Fig. 3 Types of construction
- Take note of and observe the information on the rating plate and warning and informative
notices on the motor.
- Observe the permitted transverse and axial forces (see project planning instructions).
Axial forces are not permitted on motors with an integrated brake.
- Check for compliance with the conditions (e.g. temperature, site altitude) at the assembly
- It is forbidden to use them in areas at risk of explosion.
- Remove all anti-corrosion agents from the shaft end (use commercially available
solvent).
- Ensure that waste heat is adequately dissipated.
It is recommended to maintain a clearance of 100 mm from adjacent parts on at least
three sides.
- Tighten the flanges equally, avoid distortions when tightening the fixing screws. Use
hexagon socket head cap screws, strength class at least 8.8.
- In the case of a vertical installation with the shaft end at the top, ensure that no fluid
penetrates into the upper bearing.
- Lifting eye-bolts which have been screwed in may be removed after the motor has been
installed.
- Turn the output elements by hand. If grinding noises occur, eliminate the cause or
contact the manufacturer.
- Please observe the tightening torques to be applied to the motor flange fastening screws:
Motor
ISO 4762
screw
ISO 7092
washer
Tightening torque for screws (not for
electrical connections) in Nm
1FK701.
M4
4 (d2 = 8)
2,2
1FK702.
M5
5 (d2 = 9)
4
1FK703.
M6
6 (d2 = 11)
8
1FK704.
M6
6 (d2 = 11)
8
1FK706.
M8
8 (d2 = 15)
20
1FK708.
M10
10 (d2 = 18)
35
1FK710.
M12
12 (d2 = 20)
60
IM B 5
IM V 1
IM V 3