Siem Nova 6110-A1 CURET MAX User And Maintenance Manual Download Page 10

USER and MAINTENANCE MANUAL 

6110 A1 and 6110 A2 

Manufacturer: Siem Nova S.r.l. Legal and operational offices Via C. Varalli, 1 20087 ROZZANO (Milano) MADE IN ITALY 
Product: SURGICAL ASPIRATOR MOD: 

6110 A1 MAX - 6110 A2 SPEEDY                 

 

 

 

 

 

 

 

 

 

 

Updated: 2018-01-09 

 

reproduction forbidden 

Pag: 10 di 10 

 

 

RECOMMENDED SEPARATION DISTANCES BETWEEN RADIOCOMMUNICATION DEVICES 
The  surgical  suction  equipments  6110-A1  and  6110-A2  Don´t  generate  electromagnetic  noises  and  are  not  influenced  by 
external  electromagnetic  noises,  anyhow  it  is  better  to  use  it  in  an  electromagnetic  environment  in  which  radiated  RF 
disturbances under control. The customer or the 6110-A1 and 6110-A2 operator of the device can help prevent electromagnetic 
interference by maintaining a minimum distance between mobile and portable RF communication equipment (transmitters) and 
the  6110-A1  and  6110-A2  device  as  recommended  below,  in  relation  to  the  maximum  output  power  the  communications 
equipment. 
 

 
 

Maximum  nominal  power  of  the 
transmitter output (W) 

Separation distance to the frequency of the transmitter (m) 
 
From 150 kHz to 80 MHz 
d=1,2 x √P 

from 80 kHz to 800 MHz 
d=1,2 x √P 

From 800 kHz to 2,5 GHz 
d=2,3 x √P 

0,01 

0.12 

0.12 

0.23 

0,1 

0.38 

0.38 

0.73 

1.2 

1.2 

2.3 

10 

3.8 

3.8 

7.3 

100 

12 

12 

23 

For  transmitters  with  a  maximum  rated  output  power  not  listed  above,  the  recommended  separation  distance  "d",  in  meters 
(m)  can  be  calculated  using  the  equation  applicable  to  the  frequency  of  the  transmitter,  where  "p"  is  the  maximum  output 
power 

of 

the 

transmitter 

in 

watts 

(W) 

according 

to 

the 

transmitter 

manufacturer.  

Note  1:  At  80  MHz  and  800  MHz,  the  exposure  distance  for  the  higher  frequency  range  is  applicable. 
Note 2: These guidelines may not apply to all situations. Electromagnetic propagation is affected by absorption and reflection 
from structures, objects and people. 
 

 

12 SPARE PARTS 

Use only accessories or spare parts supplied by Siem nova srl. The use of spare parts not supplied from Siem 

Nova Srl could invalidate the warranty. 

 

 

13 WARRANTIES  

Siem Nova srl (or his authorized distributor) warrants the device will be free from defects in materials and 

workmanship for a period of 2 years from the date of delivery.  
Faulty  material  will  be  replaced  free  of  charge  during  this  period  if  not  resulting  from  abuse  or  misapplication. 
Transport costs are not included. The warranty includes defects in materials, components and/or workmanship only 
if: 
  
A.

 

THE DEVICES ARE USED IN RESPECT TO ALL INSTRUCTIONS OF OPERATOR’S MANUAL;  

B.

 

MAINTENANCE IS DONE BY SIEM-NOVA SRL AUTHORIZED PERSONNEL;  

C.

 

THE ACCESSORIES ARE SUPPLIED BY SIEM NOVA  

 

This will not apply to parts subject to wear and tear in use (i.e: filters, power cord, lid and canisters). 
To  better  ensure  compliance  with  this  warranty  we  recommend  the  exclusive  use  of  spare  parts  supplied  by  Siem 
Nova srl. 
The  right  to  the  replacement  of faulty parts will not be recognized by Siem nova srl if any work has been made on 
the equipments by unauthorized persons. 
 
 
14 Technical features update 

In order to continuously improve performance, safety and reliability, all products medical devices from Siem 

Nova  Srl  are  periodically  reviewed  and  changes.  The  instruction  manuals  are  therefore  amended  to  ensure  their 
continued  compliance  with  the  characteristics  of  the  input  devices  on  the  market.  If  the  instruction  manual 
accompanying  this  device  is  lost,  you can obtain from the manufacturer a copy of the version corresponding to the 
device provided supplying serial number on the device label. 
 

 

 
 
 

 
 
 
 
 

Summary of Contents for 6110-A1 CURET MAX

Page 1: ...s symbol indicates the humidity limitation for operation transport and storage This symbol indicates the atmospheric pressure limitation for operation transport and storage This symbol indicates the t...

Page 2: ...er or liquids 24 Never touch with wet hands electrical parts 25 If the pumps get wet rub with dry towel Do not dry in a microwave 26 Do not touch the suction pumps when they have fallen into water Unp...

Page 3: ...ter 11x11 mm n 2 66609 Hydrophobic LIQUID STOP Filter n 2 66233 Silicon tube 7x13mm 4 m 81016 Pneumatic footswitch n 1 60777 Change over suction switch n 1 OPTIONAL 60972 Polycarbonate jar 2000 ml 900...

Page 4: ...FILTER 11X11mm ANTIVIRAL ANTIBACTERIAL HYDROPHOBIC FILTER SILICONE PIPE CONNECTOR YELLOW RUBBER CAP LIQUID STOP HYDROPHOBIC FILTER POLYCARBONATE CANISTER 2000ml PNEUMATIC FOOTSWITCH WHEELS WITH BRAKE...

Page 5: ...ging is damaged Do not reuse disposable use or sterile accessories 4 2 Assembly of the canister a check if the overflow valve is fixed on the lid of the canister and if the float with sealing is insid...

Page 6: ...ch on proper position the light on control panel will turn ON 3 If present test the jar switch by turning it left or right 4 Set vacuum regulator to position max 5 Close the VACUUM tube with a finger...

Page 7: ...ials only 1 Remove the lid of reusable canister 2 disassembly the cage of the overflow valve and the overflow valve 3 Clean components in hot water 60 70 C containing a detergent with a pH range betwe...

Page 8: ...ses and verifying smooth working operations 3 Check the mechanical integrity of the aluminium case the penetration of external material could damage the equipment or create danger to the operators 4 C...

Page 9: ...canister 20 kg 48 5 lbs approx max vacuum level 675 mmHg 90 kPa 0 9bar 5 CEI EN60601 1 Classification Insulation Class I device Applied part type B Device not suitable for use in presence of flammabl...

Page 10: ...pplicable Note 2 These guidelines may not apply to all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people 12 SPARE PARTS Use only access...

Reviews: