RECOMMENDED SEPARATION DISTANCES BETWEEN RADIOCOMMUNICATION DEVICES
The surgical suction equipments 6110-A1 and 6110-A2 Don´t generate electromagnetic noises and are not influenced by
external electromagnetic noises, anyhow it is better to use it in an electromagnetic environment in which radiated RF
disturbances under control. The customer or the 6110-A1 and 6110-A2 operator of the device can help prevent electromagnetic
interference by maintaining a minimum distance between mobile and portable RF communication equipment (transmitters) and
the 6110-A1 and 6110-A2 device as recommended below, in relation to the maximum output power the communications
equipment.
Maximum nominal power of the
transmitter output (W)
Separation distance to the frequency of the transmitter (m)
From 150 kHz to 80 MHz
d=1,2 x √P
from 80 kHz to 800 MHz
d=1,2 x √P
From 800 kHz to 2,5 GHz
d=2,3 x √P
0,01
0.12
0.12
0.23
0,1
0.38
0.38
0.73
1
1.2
1.2
2.3
10
3.8
3.8
7.3
100
12
12
23
For transmitters with a maximum rated output power not listed above, the recommended separation distance "d", in meters
(m) can be calculated using the equation applicable to the frequency of the transmitter, where "p" is the maximum output
power
of
the
transmitter
in
watts
(W)
according
to
the
transmitter
manufacturer.
Note 1: At 80 MHz and 800 MHz, the exposure distance for the higher frequency range is applicable.
Note 2: These guidelines may not apply to all situations. Electromagnetic propagation is affected by absorption and reflection
from structures, objects and people.
12 SPARE PARTS
Use only accessories or spare parts supplied by Siem nova srl. The use of spare parts not supplied from Siem
Nova Srl could invalidate the warranty.
13 WARRANTIES
Siem Nova srl (or his authorized distributor) warrants the device will be free from defects in materials and
workmanship for a period of 2 years from the date of delivery.
Faulty material will be replaced free of charge during this period if not resulting from abuse or misapplication.
Transport costs are not included. The warranty includes defects in materials, components and/or workmanship only
if:
A.
THE DEVICES ARE USED IN RESPECT TO ALL INSTRUCTIONS OF OPERATOR’S MANUAL;
B.
MAINTENANCE IS DONE BY SIEM-NOVA SRL AUTHORIZED PERSONNEL;
C.
THE ACCESSORIES ARE SUPPLIED BY SIEM NOVA
This will not apply to parts subject to wear and tear in use (i.e: filters, power cord, lid and canisters).
To better ensure compliance with this warranty we recommend the exclusive use of spare parts supplied by Siem
Nova srl.
The right to the replacement of faulty parts will not be recognized by Siem nova srl if any work has been made on
the equipments by unauthorized persons.
14 Technical features update
In order to continuously improve performance, safety and reliability, all products medical devices from Siem
Nova Srl are periodically reviewed and changes. The instruction manuals are therefore amended to ensure their
continued compliance with the characteristics of the input devices on the market. If the instruction manual
accompanying this device is lost, you can obtain from the manufacturer a copy of the version corresponding to the
device provided supplying serial number on the device label.