USER and MAINTENANCE MANUAL
6110 A1 and 6110 A2
Manufacturer: Siem Nova S.r.l. Legal and operational offices Via C. Varalli, 1 20087 ROZZANO (Milano) MADE IN ITALY
Product: SURGICAL ASPIRATOR MOD:
6110 A1 MAX - 6110 A2 SPEEDY
Updated: 2018-01-09
reproduction forbidden
Pag: 1 di 10
ASSISTANCE
Read the instruction manual before using the device.
This manual must be kept with the device for later reference.
SIGNS AND SYMBOLS
This symbol indicates the
compliance with the
essential requirements of
the Directive 93/42/ EEC
of 14 June 1993
concerning medical
devices. Reference IMQ
Spa - Milan
This symbol
indicates an
insulation class I
device.
This symbol indicates
to follow instructions
for use.
This symbol indicates the
date of production (four
digits for the year and two
digits for the month).
This Symbol
indicates a type B
applied part.
This symbol indicates
to consult instructions
for use.
This symbol indicates the
manufacturer.
This symbol
indicates alternate
current
This symbol indicates
the foot switch.
This symbol indicates that
interferences may occur in
the vicinity of equipment
marked with this symbol
This symbol
indicates a single
use device. Do not
reuse the device.
This symbol indicates a
CAUTION or WARNING
associated with the
device.
This symbol indicates the
humidity limitation for
operation, transport and
storage
This symbol
indicates the
atmospheric
pressure limitation
for operation,
transport and
storage.
This symbol indicates
the temperature
limitation for
operation, transport
and storage.
This symbol indicates to
keep the device away from
sunlight
This symbol
indicates to keep the
device dry.
IP33
This symbol indicates
the protection against
harmful effects due to
ingress of solid foreign
objects and against
harmful effects due to
the ingress of water.
This symbol indicates do
not dispose the device
together with unsorted
municipal waste (for EU
only).
This symbol indicates
do not immerse in
water or other liquid
PRESSURE MEASURE UNIT CONVERSION TABLE
Legenda:
bar, KPa, cm Hg, cm H2O are all measure unit of pressure (vacuum)
bar
KPa
cm Hg
cm H2O
1 bar
1
100
75.006
1019.72
1 KPa
0.01
1
0.75006
10.1972
1 cm Hg
0.133
1.333
1
13.595
1 cm H2O
0.098
0.00098
0.07355
1
1
APPLICATION
The suction equipments 6110-A1 and 6110-A2 are approved exclusively for the use as described in this user and maintenance
manual. Siem Nova can only warranty the safe functioning of the equipments when the 6110-A1 and 6110-A2 are used with the
Siem Nova accessories.
Please read and observe these warning and safety instructions before use the device.
Please note that these instructions for use are a general guide for the use of the product.
Medical matters must be addressed by a physician.