H39.MFVRS009EN-00
02.2019
59
/
64
Assembly instructions
Multi-point locks, key operated
BS 6000 OF/OR, BS 6000, BS 6600
1
f
Turn the two eccentric screws
[1] to the left or right up to 90°.
T 10
1.3 Nm
f
Tighten the three fixing screws
of the Q adjustment firmly.
2 x
f
Close the door and lock with a
double turn.
f
Run the conical locking elements
into the Q adjustment and
laterally press the door against
the seal.