Siegenia AERO AEROMAT VT WRG 1000 Assembly Instructions Manual Download Page 10

10

AEROMAT VT WRG 1000 

Assembly Instructions

Last update: 10.2014

Liability

Intended use

Any use of this product that is not in accordance with its intended use, or any adaptation of or modification to the product 
and its associated components for which our express consent has not been obtained, is strictly prohibited. We accept no 
liability whatsoever for any material losses or injury to people caused by failure to comply with this stipulation.

Product liability

Our products are guaranteed – subject to correct installation and proper use – for a period of one year from the date of 
receipt by a company (according to our general terms and conditions) or as otherwise agreed, and for a period of two years 
for end consumers, in accordance with statutory provisions. As part of our ongoing improvements, we reserve the right to 
replace individual components or entire products. Consequential losses resulting from defects are excluded from the 
warran ty within the limits of the law. The warranty shall become void if modifications that are unauthorised by us or have not 
been described in this documentation are performed on the product and/or individual components, or if the product and/or 
indi vidual components is/are dismantled or partly dismantled, and the defect is due to the changes made.

Exclusion of liability

The product and its components are subject to stringent quality controls. As a result, they function reliably and safely when 
used correctly. Our liability for consequential losses and/or claims for damages is excluded, except in the case of wilful 
mis conduct or gross negligence, or where we are responsible for injury to life, limb or health. Strict liability under the German 
Product Liability Act (Produkthaftungsgesetz) remains unaffected. Liability for the culpable violation of significant contractual 
obligations also remains unaffected; liability in this case is limited to losses that are specific to the contract and that could 
have been foreseen. The above regulations do not imply a change in the burden of proof to the detriment of the consumer.

EU Declaration of Conformity

We, SIEGENIA KG, declare under our own responsibility that the product complies with the provisions of Directives 
2008/108/EC and 2006/95/EC of the Council of the European Union.

Environmental protection

Although our products do not fall within the scope of the German Electrical and Electronic Equipment Act, SIEGENIA will 
continue to meet the requirements of this Act and will endeavour to completely eliminate the use of substances that are 
hazardous to the environment as soon as this becomes technically feasible. Electrical products should not be disposed of as 
household waste.

Feedback on documentation

We are always happy to receive comments and suggestions for the improvement of our documentation. Please e-mail us your 
comments to ‘[email protected]‘.

Summary of Contents for AERO AEROMAT VT WRG 1000

Page 1: ...embly Instructions AEROMAT VT WRG 1000 Sound absorbing ventilator with heat recovery Window hardware Door hardware Sliding door hardware Ventil ation technology building technology Ventil ation technology ...

Page 2: ...OMAT VT WRG 1000 Assembly Instructions Last update 10 2014 Contents Target group of this documentation 3 Intended use 3 Safety notices 4 Installation 5 Mains supply 8 Technical specifications 9 Liability 10 ...

Page 3: ...exterior windows walls of permanent structures in accord ance with our installation and design documents as well as the specifications of our assembly instructions and is only suit able for the ventilation of enclosed rooms The AEROMAT VT WRG 1000 must be installed in the intended installation position horizontal or vertical The intended in stallation position is based on the weather grille that i...

Page 4: ...cludes regular inspection and replacement of filters Safety notices This unit can be used by children aged 8 and above as well as by people with physical sensory or mental difficulties or with a lack of experience and knowledge as long as they are supervised or have been instructed in how to use the unit safely and understand the resulting risks Children must not play with the unit Cleaning and us...

Page 5: ...quality of the air being drawn in The maximum permissible area load is 1 000 kg per running metre of ventilator length Installation options Installation in the window sill Concealed installation in the win dow sill Concealed installation in the window sill with channel Installation in the window lintel Concealed installation in the win dow lintel Vertical installation next to the window AEROMAT VT...

Page 6: ...adding Attention Depending on the installation location of the AEROMAT VT WRG 1000 it may be necessary to mask up with adhesive tape areas which may be exposed to rainfall Example Installation concealed in the wall with wall duct Example Installation concealed in the lintel foil adhesive tape AEROMAT VT exterior insulation adhesive tape AEROMAT VT adhesive tape foil adhesive tape exterior insulati...

Page 7: ... the casing profiles with a rivet We recommend that you use SIEGENIA aluminium mounting brackets AEROMAT VT WRG 1000 with 911 CW weather grille AEROMAT VT WRG 1000 with 911 HW weather grille Dimension Meaning a Mounting area for bracket b Screw and drilling area e g for window plugs or mounting screws c Installation depth A Bracket 20 x 20 x 2 optional B Z profile optional C Stop profile optional ...

Page 8: ...d electrician All work on the 230 V AC mains power supply must be carried out in compliance with the current German VDE regula tions e g VDE 0100 and any relevant country specific requirements Switch off or unscrew the circuit breakers Important If the AEROMAT VT WRG 1000 is connected directly to the 230 V AC mains power supply a mains isolator must be installed by the customer Wire the circuit ac...

Page 9: ...evel 2 Approx 42 m3 h without filter Approx 36 m3 h with filter Heat recovery efficiency3 max 62 Internal noise at blower level 14 LpA ca 17 dB A Internal noise at blower level 24 LpA ca 34 dB A Supply voltage 230 V Unit operating voltage 24 V Power consumption at blower level 1 10 W Power consumption at blower level 2 21 W Protection class II Mains supply 230 V 50 Hz Circuit breaker Thermo fuse i...

Page 10: ... its components are subject to stringent quality controls As a result they function reliably and safely when used correctly Our liability for consequential losses and or claims for damages is excluded except in the case of wilful mis conduct or gross negligence or where we are responsible for injury to life limb or health Strict liability under the German Product Liability Act Produkthaftungsgeset...

Page 11: ......

Page 12: ... 2811312 China Phone 86 316 5998198 France Phone 33 3 89618131 Germany Phone 49 271 39310 Great Britain Phone 44 2476 622000 Hungary Phone 36 76 500810 Italy Phone 39 02 9353601 Poland Phone 48 77 4477700 Russia Phone 7 495 7211762 South Korea Phone 82 31 7985590 Switzerland Phone 41 33 3461010 Turkey Phone 90 216 5934151 Ukraine Phone 380 44 4637979 You can find address details for our internatio...