Original operating instructions
AEROMAT VT RS2
10.4
Operation via smartphone or tablet
(AEROMAT VT RS2
smart only)
The.
AEROMAT VT RS2
.smart.can.be.controlled.by.a.
tablet.or.smartphone.and.offers.additional.device.
functions.via.the.SIEGENIA.Comfort.app.
10.4.1
Teaching in the unit
Please.follow.the.enclosed.quick.start.instructions.
).to.integrate.the.device.in.your.
home.WIFI.
10.4.2
Unit functions in the app
•
Blower.performance:.the.blower.performance.can.
be set manually.
•
Warning.(filter.replacement):.as.soon.as.a.filter.
replacement.is.required,.this.will.be.indicated.as.a.
warning.
11
Maintenance
WARNING
Electrically.operated.unit
Risk of fatal injury from electric shock or fire
•
Pull.the.mains.plug.out.of.the.socket.prior.to.every.
cleaning.process.or.maintenance.work..Never.pull.at.
the.cable.to.disconnect.the.device.from.the.electricity.
grid.
•
For.all.devices.with.a.fixed.connection.to.the.230.V.AC.
mains.power.supply,.switch.off.all.poles.of.the.feeder.
11.1 Cleaning
When.cleaning.the.
AEROMAT VT RS2
,.do.not.allow.
any.liquid.to.get.inside.the.unit.
•
Never.use.cleaning.agents.that.are.aggressive.or.
contain.solvents,.or.sharp-edged.objects,.as.these.
may.damage.the.surfaces.of.the.casing.
•
Never.clean.the.unit.with.a.high-pressure.cleaner.or.
steam-jet.cleaner.
•
Clean.the.
AEROMAT VT RS2
.with.a.cloth.moistened.
with.a.mild.soap.solution.or.cleaning.agent.
•
Only.clean.the.dust.filter.ISO.Coarse.55%.manually.
(e..g..with.vacuum.cleaner,.wash.out.with.a.grease-
dissolving.cleaning.agent)..Do.not.wash.the.filter.in.
a.washing.machine!
11.2
Maintenance intervals
Check and
clean
component
or replace
air.canals.(foam.
elements) 1
every 12
months
depending.on.
the.level.of.
soiling
ISO.ePM10.50%.
filter.
1
–
every 12
months.or.
when.the.
filter.change.
indicator.lights.
up
ISO.Coarse.55%.
filter
every 12
months.or.
when.the.
filter.change.
indicator.lights.
up
depending.on.
the.level.of.
soiling
1)
ISO ePM10 50% filters must not be cleaned, they must be
replaced. Only use the original filters from SIEGENIA. You can
purchase replacement filters from SIEGENIA or from specialist
retailers.