H47.FENS083EN-02
03.2021
11/20
Original operating instructions
AEROMAT VT RS2
AERO
9
Membrane key and LED display
9.1
Operating status
Membrane key / LED
Operating status
Blower level 0
(unit.is.switched.off)
1.LED.lights.
up.red
Blower level 1
2.LEDs.light.
up.red
Blower level 2
9.2
Filter replacement indicator
Membrane key / LED
Malfunction Solution
Membrane
key.flashes.
blue
Filter soiled
Replace.
the.filter
Depending.on.the.equipment,.the.filter.change.is.
displayed.in.addition.to.the.current.operating.mode.
M5.filters.must.not.be.cleaned,.they.must.be.
replaced.(replace.filter.see.page.
13)
10
Operation
According.to.the.design,.the.membrane.key.is.
positioned.on.the.LH.or.RH.in.the.
AEROMAT VT RS2
..If.it.is.located.on.the.RH.side,.the.
membrane.key.is.turned.180°.(see.figure).
1.
Open.sliders
2.
Adjust.the.required.blower.level.using.either.the.
membrane.key.or.the.external.switch
Following.a.power.failure,.the.AEROMAT.VT.RS2.
switches.to.the.last.level.to.be.used.
10.1
Adjustment of the blower level using the
membrane key
•
By.pressing.the.membrane.key.several.times,.you.
can.activate.the.required.blower.levels.(relaying).
Blower level 0
Blower level 1
Blower level 2
10.2
Adjustment of the blower level using the
external switch
•
You.can.activate.the.required.blower.levels.directly.
by.pressing.the.external.switch.(without.relaying).
If.the.membrane.key.is.pressed.when.an.external.
switch.is.installed,.the.next.blower.level.will.be.
activated..Pressing.the.external.switch.again.takes.
you.back.to.the.required.blower.level..
0
0
1
2
-Au-
-to-
0
0
1
2
-Au-
-to-
0
0
1
2
-Au-
-to-
Blower level 0
Blower level 1
Blower level 2
10.3
Blower level 3
If.you.need.a.3..blower.level,.you.can.enable.this.in.the.
programming.mode.
For.information.on.the.programming.mode.see: