![SIEB & MEYER SD2B Hardware Description Download Page 62](http://html.mh-extra.com/html/sieb-and-meyer/sd2b/sd2b_hardware-description_1264950062.webp)
Code
Error message
Error reaction
Possible reason
E35
(0x523)
(1315
d)
Error in external power supply unit
Drive is immediately disabled,
motor coasts to standstill.
▶
Error message from external power
supply unit; power supply is
switched off.
E36
(0x524)
(1316
d)
Encoder 0 monitoring
Motor is stopped by current moni‐
toring via short-circuit of the motor
phases.
▶
Connection of encoder 0 is faulty
▶
Broken cable
E37
(0x525)
(1317
d)
Ballast circuit load (I²t ballast
resistor)
Drive is immediately disabled,
motor coasts to standstill.
Ballast circuit load due to:
1
I²t
1
Wrong dimensioning, too much
energy supplied to R
Ballast
, broken
cable, no bridge at R
Ballast
(int./
ext.)
2
(VCE) desaturation detection
or: DC DC converter over‐
load
(only 0362144xy)
2
Bridge at R
Ballast
is not correct,
short circuit of insulation etc.
Or: internal hardware fault
(only
0362144xy)
E37
(0x525)
(1317
d)
DC DC converter overload
(only
0362161xy)
Power supply unit will be discon‐
nected from mains.
▶
Overload at voltage converter of
DC link
E38
(0x526)
(1318
d)
Actual speed value greater than
overspeed threshold
Motor is stopped by current moni‐
toring via short-circuit of the motor
phases.
(1)
▶
Wrong parameters
▶
Motor connected incorrectly
E39
(0x527)
(1319
d)
Tracking error monitoring and
motor slowdown
Motor is stopped by current moni‐
toring via short-circuit of the motor
phases.
(1)
▶
Wrong parameters
▶
Motor connected incorrectly
▶
Mechanical problems
E40
(0x528)
(1320
d)
Motor feedback
Motor is stopped by current moni‐
toring via short-circuit of the motor
phases.
(1)
▶
Connection of motor feedback
faulty
▶
Broken cable
E41
(0x529)
(1321
d)
Motor phase lost
Motor is stopped by current moni‐
toring via short-circuit of the motor
phases.
(1)
Motor connection/configuration is faulty:
1
No motor connected
1
No motor connected / incorrect
wiring, broken cable
2
Wrong motor connected
2
Wrong parameters
E42
(0x52A)
(1322
d)
Overvoltage in DC link
Drive is immediately disabled,
motor coasts to standstill.
▶
No ballast resistor is connected or
ballast resistor is dimensioned too
small, i.e. X41/X63 not connected
E43
(0x52B)
(1323
d)
Undervoltage in DC link
Drive is immediately disabled,
motor coasts to standstill.
▶
DC link not connected
E44
(0x52C)
(1324
d)
Commutation lost
The following list of error
messages includes a note for
which drive function the error
might appear.
▶
1
HSBLOCK
▶
2
FPAM
▶
3
SVC
▶
4
HSPWM
▶
5
VF
Drive is immediately disabled,
motor coasts to standstill.
The error E44 is triggered in case of
wrong current feed of the motor during
operation without sensor.
Possible reason: wrong parameter
setting or overload of the motor. The
error depends on the drive function. For
details refer to the corresponding setup
instructions.
1
EMF monitoring
1, 2, 3 4
2
Flux monitoring
4
3
Over current monitoring
4
Status Display and Error Messages
W
62
Drive Amplifier SD2B / SD2B plus - Hardware Description
10
Summary of Contents for SD2B
Page 1: ...Drive Amplifier SD2B SD2B plus Hardware Description P TD 0000312 8 2019 09 09 SIEB MEYER W ...
Page 4: ...Chapter Overview W 4 Drive Amplifier SD2B SD2B plus Hardware Description ...
Page 8: ...Content W 8 Drive Amplifier SD2B SD2B plus Hardware Description ...
Page 12: ...General Information W 12 Drive Amplifier SD2B SD2B plus Hardware Description 2 ...
Page 22: ...Unit Assembly Complying EMC W 22 Drive Amplifier SD2B SD2B plus Hardware Description 4 ...
Page 26: ...Drive Amplifier SD2B SD2B plus W 26 Drive Amplifier SD2B SD2B plus Hardware Description 5 ...
Page 32: ...Device variant SD2B W 32 Drive Amplifier SD2B SD2B plus Hardware Description 6 ...
Page 38: ...Device variant SD2B plus W 38 Drive Amplifier SD2B SD2B plus Hardware Description 7 ...
Page 66: ...Status Display and Error Messages W 66 Drive Amplifier SD2B SD2B plus Hardware Description 10 ...
Page 80: ...Safety Circuit Restart Lock STO W 80 Drive Amplifier SD2B SD2B plus Hardware Description 13 ...
Page 82: ...Appendix W 82 Drive Amplifier SD2B SD2B plus Hardware Description 14 A ...