NOTICE
Voltage peaks during braking operation
During braking of high inertial masses and/or when using short braking times the
DC main voltage can increase significantly depending on the parameterized supply
voltage.
▶
supply voltage 24 V
DC
→ max. overvoltage 40 V
DC
▶
supply voltage 48 V
DC
→ max. overvoltage 70 V
DC
▶
supply voltage 80 V
DC
→ max. overvoltage 110 V
DC
The connected power supply unit must be designed for this voltage. If not, you
need to decouple the main voltage by means of a blocking diode to avoid damage
to the power supply unit (see connection example
6.5
Connectors
Fig. 5: Connectors of SD2B (top view)
You can order the appropriate connector kit for SD2B at SIEB & MEYER
(article No. 32299576).
W
Device variant SD2B
Drive Amplifier SD2B / SD2B plus - Hardware Description
31
6
Summary of Contents for SD2B
Page 1: ...Drive Amplifier SD2B SD2B plus Hardware Description P TD 0000312 8 2019 09 09 SIEB MEYER W ...
Page 4: ...Chapter Overview W 4 Drive Amplifier SD2B SD2B plus Hardware Description ...
Page 8: ...Content W 8 Drive Amplifier SD2B SD2B plus Hardware Description ...
Page 12: ...General Information W 12 Drive Amplifier SD2B SD2B plus Hardware Description 2 ...
Page 22: ...Unit Assembly Complying EMC W 22 Drive Amplifier SD2B SD2B plus Hardware Description 4 ...
Page 26: ...Drive Amplifier SD2B SD2B plus W 26 Drive Amplifier SD2B SD2B plus Hardware Description 5 ...
Page 32: ...Device variant SD2B W 32 Drive Amplifier SD2B SD2B plus Hardware Description 6 ...
Page 38: ...Device variant SD2B plus W 38 Drive Amplifier SD2B SD2B plus Hardware Description 7 ...
Page 66: ...Status Display and Error Messages W 66 Drive Amplifier SD2B SD2B plus Hardware Description 10 ...
Page 80: ...Safety Circuit Restart Lock STO W 80 Drive Amplifier SD2B SD2B plus Hardware Description 13 ...
Page 82: ...Appendix W 82 Drive Amplifier SD2B SD2B plus Hardware Description 14 A ...