DIP switch
Single-axis drive amplifier
Double-axis drive amplifier
14
- - -
Drive amplifier 7, drive B
15
Drive amplifier 8
Drive amplifier 8, drive A
16
- - -
Drive amplifier 8, drive B
The following example shows the settings of the DIP switches for 4 double-axis drive
amplifiers
and
4 single-axis drive amplifiers (mixed operation):
DIP switch
Single-axis drive amplifier
Double-axis drive amplifier
1
- - -
Drive amplifier 1, drive A
2
- - -
Drive amplifier 1, drive B
3
- - -
Drive amplifier 2, drive A
4
- - -
Drive amplifier 2, drive B
5
- - -
Drive amplifier 3, drive A
6
- - -
Drive amplifier 3, drive B
7
Drive amplifier 4, drive A
8
- - -
Drive amplifier 4, drive B
9
Drive amplifier 5
- - -
10
- - -
- - -
11
Drive amplifier 6
- - -
12
- - -
- - -
13
Drive amplifier 7
- - -
14
- - -
- - -
15
Drive amplifier 8
- - -
16
- - -
- - -
6.2
Connector Pin Assignment
6.2.1
X4/ X3 – SERVOLINK 4
SERVOLINK 4: optical input (X4) and optical output (X3)
The fiber optic connectors for SERVOLINK 4 are located at the bottom side of the de-
vice.
Connector
SIEB & MEYER article number
12540102
Inputs (black)
12540103
12540202
Outputs (gray or white)
12540203
Cable connector
(TOSLINK F05)
32022900
NOTICE
Risk of cable damage
If you pull the optical fiber cable with its connector too fast out of the connector, the cable
may be damaged.
→ When unplugging the cable, hold the fiber optic connector and pull the cable care-
fully out of the connector.
31
Gateway 0362157A - PROFINET IO to SERVOLINK 4 and Safety
Connectors, Switches and Displays