9. Select the PROFINET I/O Controller in the selection list.
10. Select “Device x (EL6631)” and run the scan. Confirm “Devices should be reloaded
before scanning!” with “Yes”.
11. Select the found gateway and click on the button “Add Devices”.
12. Confirm the inquiry “OnlineScan for real configuration?” with “Yes”. Now, another
scan reads the current gateway configuration.
Then, the gateway will be entered in the Solution Explorer containing all available drives.
Add and configure several gateways
1. If several gateways are connected, select one gateway after the other as described
above.
2. Via the button “Start Flash” you can check the assigned real device. Then, the LED
“SF” of the corresponding gateway flashes.
23
Gateway 0362157A - PROFINET IO to SERVOLINK 4 and Safety
Gateway 0362157A