![Sidekick SK-8RG Owner'S Manual Download Page 18](http://html1.mh-extra.com/html/sidekick/sk-8rg/sk-8rg_owners-manual_1264885018.webp)
18
TEMPERATURE SENSOR REPLACEMENT
Open the unit (see OPENING). Locate the heating tank. The temperature sensor screws
into the side of the heating tank. There are 2 wires connecting the sensor. One goes to a
solder lug, and the other is soldered to a black wire. Cut away both wires (the wires are
interchangeable). Use a coin (quarter) to unscrew the old sensor (DO NOT USE a
screwdriver. it may slip into and break the sensor).
Wrap the new sensor with 4 wraps of teflon tape and screw into the heat tank with a coin
(quarter). Solder the 2 wires where you cut the old wires. Close the unit and do TEMP
CALIBRATE (see SPECIAL FUNCTIONS) to match the sensor to the PC board.
SOLUTION LEVEL SETTING
Open the unit (see OPENING). Locate the 5 level sensors on the heat tank. The sensor
closest to the left corner is low level (4 oz -120 ml) followed by: 9 oz, 15 oz, 22 oz and 29
oz. Pour the proper amount of water (start with 4 oz then add 5 oz etc.) into the heat tank.
Hold the sensor where it passes over the tank wall with one hand and bend the end of
the sensor with the other hand so that the sensor just touches the water. Empty the heat
tank by closing the unit and running DRAIN (see SPECIAL FUNCTIONS).
SHIPPING the UNIT
Prepare the unit by running CLEAN LINES (see SPECIAL FUNCTIONS). Open the unit (see
OPENING) and wipe up any loose solutions. Tie down the 2 pumps (through the holes in
the base) with strong twine. Remove the magnetic stirrer (white pill) from inside the heat
chamber. Close the unit. Remove and keep stir bar, plug and power cord.
Place the unit in a plastic bag. Use as much packing (balled newspapers, bubble wrap
etc. <please do not use small styrofoam chunks>) as possible to cushion the unit from
the walls of the box.
PARTS LIST SK-8RG Always specify model and serial number.
AF-SVG
Selector Valve
450.- AF-SPL
Spindle 4-roll
60.-
SK8-HT
Heat tank
350.- SK8-SPL
Spindle 8-roll
90.-
AF-TS
Temperature sensor
50.- AF-DD
Disc dryer
150.-
SK8-PC
Printed circuit brd
250.- AF-SPD
Disc spindle
60.-
AF-PM
Program module
50.- DP-RET
Retainer for discs
20.-
AD-DISP
Display
90.- SK8-DEXT
Disc spind extension
10.-
AF-TR
Transformer
75.- AF-BOT5
Bottle 5 Gal
20.-
AD-P
Pump
120.- ADC-LEV
Sensor for dump btl
50.-
AF-DRT
Dryer internal
50.- AF-FV
Float valve
15.-
AF-DR8
Wall dryer 8 roll
280.- AF-ICE
Water connect kit
10.-
AF-V3
Valve triple
180.- AF-BOT2L
Bottle 2 liter
5.-
AF-VCL
Valve coil 120V
25.- AF-REEL
Film reels Paterson
10.-
AF-VST
Valve seat
5.- AF-LNCRD
Power cord
10.-
AF-ROT
Rotate motor
75.- DP-SW
Switch power. 2 pole
7.-
AF-STAP
Staple bushing
10.- DP-PSW
Push switch
5.-
AF-STSL
Staple sleeve (2)
1.- AF-SW
Switch save
3.-
AF-4X5
4x5 holder
90.- AF-BOT1G
Bottle 1 gal (4 l)
7.-
SK8R-MV
Metering valve
90.- SK8R-BOT
Replenishing bottle
60.-
SK8-D4
Process drum 4-roll
140.- AF-C120
120 film clamps (3)
2.-
SK8-D8
Process drum 8-roll
160.- AF-OR
”O” ring (3)
2.-
Summary of Contents for SK-8RG
Page 13: ...13...
Page 16: ...16...
Page 19: ...19 blank sheet for page count insert wiring diagram...