Trouble shooting

Solution

Check the flexible coupling and the motor installation to ensure correct con

-

nection of the flexible coupling before re-fitting the electromotor

Re-fasten or replace the propeller and/or key.

In case of a failure inside the gearhouse, we advice to get a replacement gear-

house instead of attempting to repear the internal gear and bearing system.

If wrong, contact your dealer or distributor to obtain parts with the correct voltage.

The no load voltage should be:  

12V system =12,7V / 24V system = 25,4 V. If below 12,3V / 24,6V your bat-

teries are not in a good charge state or worn out and must be recharged or 

replaced before trying to run the thruster. 

If less than 8,5V at the thruster the voltage is to low for the thruster to operate cor-

rectly. In a 24V boat the thruster will operate down to approx. 12V, but the perfor-

mance will be very bad. Find and correct the reason for this low voltage which will 

probably be one or more of these points: main battery cable sizes and connec-

tions, battery size and condition, fuse and main power switch performance

.

If the thruster runs in both directions, try the same in the connector that goes 

into the back of the control panel. If it also works in this position, check the 

contact and wires on the back of the panel and try to engage this again by 

pushing both ON buttons simultaneously. If the panel does not turn on (see 

control light), measure the voltage between the Red and the Black in the con-

tact going into the thruster. If the voltage is good, chances are that the panel 

is not working.

If it works by the thruster, and not by the panel there is a bad contact or a 

broken lead the controlcables between these two test points.

Measure that you have the correct voltage between the Red (+) and all the 

other colours in the contact. If you do not get a reading.

 Between main minus (A1 on motor) and the blue and the grey wire connec-

ted to the sides of the main solenoids you should have the same voltage as 

between the main battery cables on the thruster.

If not, check that the internal wiring on the solenoid is ok and measure that 

there is contact through the magnetising spools of each side of the solenoid 

(measure between the red and blue on one side, and red and grey on the 

other side with an Ohm meter.). If there are no contact between these, the 

solenoid is broken and needs replacing.

If less than 10,5 V / 21V the thruster will not perform at specified effect.

If one or more brushes are loose/has no tension from the brush-spring, the 

performance will be low.

If there are growth in the tunnel, this will disturb / block the waterflow and 

especially barnacles on the propeller will greatly reduce performance.

Re-charge battery(ies), if this is not sufficient, replace battery(ies).

Check for bad cable connections, if necessary tighten/re-adjust connections.

Check cable size in accordance to manual.

Shut off thruster main switch, tap slightly on the solenoid to see if it will rele-

ase. Turn on thruster main switch. If solenoid is still in lock-in mode, replace 

solenoid.

Check

If the flexible coupling between the motor and dri

-

veshaft is not fitted correct inside the boat

 

Are the propellers in the tunnel fastened correctly 

on the prop-shaft (key present)

With the motor removed, turn the driveshaft from 

inside the boat to feel if the gears are engaging and 

turning the prop-shaft.

Check that the voltage of the electromotor are cor-

rect for your installation by their labels.

Check the voltage at the thruster between main minus 

input (A1 on motor) and main plus input point:

Check the voltage at the thruster while you are try-

ing to run it. Keep main engine(s) running to have 

continous charge to the batteries.

If the main solenoids on the thruster are not even 

trying to engage (clicking) they are probably not 

getting a "run" signal from the control system. Try 

to run the thruster without the panel by directly con-

necting the red and the blue or the red and the grey 

wires in the controlcable contact coming from the 

thruster.  

If the thruster does not run at all, or only in one direction 

in the above tests, check the internal wiring on the 

thruster motor, solenoids and electronic motor inter-

face box to be in accordance with the wiring diagram 

and ensure that all connections are clean and tight.

Check voltage at thruster when running

Check that all the brush-springs sits correctly on the 

brushes in the electromotor.

Check that the propeller, gearhouse and tunnel is 

free from growth / barnacles etc.

Solenoid flapping, most probable cause: low 

voltage.

Solenoid lock-in, auto stop of thruster, auto retry 

every 10 seconds.

» 

 The electromotor runs, but there is no thrust.

» 

 The thruster does not start at all or works only in one direction.

» 

 The thruster has an unexpected low performance.

» 

 The thruster runs for approximately 0,5 seconds every 4 seconds.

» 

 The thruster runs for approximately 0,5 seconds every 10 seconds.

Summary of Contents for SE170/250TC-IP

Page 1: ...ected thruster assembly SLEIPNER MOTOR AS P O Box 519 N 1612 Fredrikstad Norway Tel 47 69 30 00 60 Fax 47 69 30 00 70 Installation and user manual w w w s i d e p o w e r c o m sidepower sleipner no K e e p t h i s m a n u a l o n b o a r d SIDE POWER Thruster Systems ...

Page 2: ...iginal Sidepower panel is used the panel shuts off automatically 6 minutes after last use Integrated microprocessor monitors solenoids reducing wear and risk of solenoid lock in Auto stop of thruster in case of accidental solenoid lock in or if run signal is continuous for more than 3 minutes Technical specifications DECLARATION OF CONFORMITY We Sleipner Motor AS P O Box 519 N 1612 Fredrikstad Nor...

Page 3: ... to cut a stiffener stringer support for the hull integrity without checking with the boatbuilder that this can be safely done When installed in boats approved or classified according to international or special national rules the installer is responsible for following the demands in accordance with these regulations classification rules The instructions in this guide can not be guaranteed to comp...

Page 4: ...escribed on page 6 We recommend that you fit the oil feed pipe also before the tunnel is bolted to the transom 5 When fitting the tunnel ensure that there is ample sealant Sikaflex or similar in the sealing tracks of the tunnel flange and around the bolts to make a water tight fitting Fig 1 2 Bolts washers and nuts are not included as they will wary de pending on the transom thickness We recommend...

Page 5: ...ers matt both inside and outside Fig 2 Take care not to reduce the internal diameter much as this will make it more difficult to mount the thruster 8 Apply gelcoat or similar on all bonded areas 9 Install the gear leg on the stern tunnel as described in the installation manual for the thruster but fit the oil feed pipe first 10 Basic installation of the motor assembly and electrical installa tion ...

Page 6: ... SP 285 TCi k the centreline of the tunnel and the boats The propellers the lower unit must be completely inside the tunnel the gasket A to mark the centre of the holes and double ck the measurements All holes must be in line with the tunnels centreline for ise installation as the clearance between the propeller and unnel is minimal re must be no casting where the motor bracket is to be ed as this...

Page 7: ...lock nut 3 on the propeller shaft 3 Place the zinkanode 2 in its designated position and tighten the zincanodes holding screw 1 Apply a thread glue Locktite or similar to ensure that the zincanodes holding screw does not un screw itself from the propellers rotation 4 Fit the propellers to the shafts with the LH marked propeller on the port side and the RH marked propeller on the starboard side Tur...

Page 8: ...ür den Bruchteil einer Sekunde betätigen wenn dieser nicht im Wasser ist NB Wird der Elektromotor eingebaut falls das Boot noch in Bau ist so muß dieser abgedeckt werden um eine Verschmutzung von Relais und Motor zu verhindern Diese Abdeckung muß vor Benutzung des Thrusters entfernt werden 1 Remove the 4 bolts in the motorbracket 2 Turn the driveshaft in the gearhouse and the motorshaft so the key...

Page 9: ...nge von und Batterieangabe ist min Kaltstartkapazität nicht Ah Sicherung träge Ausführung angeg Stomverbrauch min 5 Min Kabel und Batteriegröße falls eine zusätzliche Batterie mit min der Kaltstartkapazität mit A angegeben im Bug installiert ist Da die am laufenden Motor anliegende Spannung die Umdre hungszahl und damit die Leistungskraft bestimmt sind Kabel mit ausreichendem Querschnitt und Batte...

Page 10: ...rol panel Control panel and control leads 10 SP75Ti SP95Ti ignition protected thruster assembly 1 2 1 2007 You can install as many panels as you wish by using optional Y connectors If two or more panels are operated at the same time in opposite directions the electronic controlbox will stop the thruster until it only receives a signal to go in one direction When using original Sidepower equipment ...

Page 11: ...P75Ti SP95Ti ignition protected thruster assembly 1 2 1 2007 Visual wiring diagram A2 A1 Fuse 9 6 8 1 2 4 5 red grey blue black grey blue brown red 6 1230i Electronic control box Thermal switch Battery 12V or 24V Battery main switch M 4 3 2 1 3 red red black 7 white 6 1232i ...

Page 12: ...gram simplified for dual joystick panel Visual connection diagram for dual joystick panel y We advice to use different battery banks for each thruster to ensure maximum performance when both are used at the same time y When using the original Sidepower control cables just connect them to the corresponding joystick y There are no plus positive power connected from the bowthruster yellow BOW STERN b...

Page 13: ... is fastened Oil tank is fitted above the waterline as required and filled with gearoil Correct drive direction as per controlpanel All electrical connections are clean dry and tight and the correct cable fuse and main switch sizes have been used The bolts holding the gearhouse and motorbracket together are tightened correctly Very important for IP protection The main power cables have securely be...

Page 14: ...have come to a complete stop before performing a directions change of the thruster as it might cause damage to the thruster If the thruster stops giving thrust while the electromotor is running chances are that there is a problem in the drive system You must then immediately stop trying to run it and turn it off as running the electromotor for more than a few seconds without resistance from the pr...

Page 15: ... try in open water first How to use Sidepower thrusters 15 SP75Ti SP95Ti ignition protected thruster assembly 1 2 1 2007 How to use a bowthruster 1 Turn main power switch for the bowthruster on Always turn off the main power switch when not onboard 2 Please take some time to exercise thruster usage in open water to avoid damages to your boat 3 Turn the controlpanel on by pushing both ON buttons on...

Page 16: ...s for the whole period between regular service lifts of the boat Consult your dealer for information on how to do this As a part of the seasonal service of your boat and before every season always check that The propeller is securely fastened The bolts holding the electric motor to the motorbracket are fastened correctly The area where the thruster is installed is clean and dry If there are signs ...

Page 17: ...noid is ok and measure that there is contact through the magnetising spools of each side of the solenoid measure between the red and blue on one side and red and grey on the other side with an Ohm meter If there are no contact between these the solenoid is broken and needs replacing If less than 10 5 V 21V the thruster will not perform at specified effect If one or more brushes are loose has no te...

Page 18: ...o so Prior to refund of the purchase price Purchaser must submit a statement in writing from a professional boating equipment supplier that the installation instructions of the Installation and Operation Manual have been complied with and that the defect remains e warranty service shall be performed only by the Warrantor or an authorized Service Centre and any attempt to remedy the defect by anyon...

Page 19: ...40 18 Complete flexible coupling N A 17 Coupling engine side 7 1457 16 Rubber element 7 1458 15 Coupling gearleg side 7 1457 14 Complete motor bracket N A 13 Bolt motor to flange 201360 12 Bolt flange to bracket 11031 11 Flange 921305 10 Bracket 10 0501 9 Complete gearleg 13 0601 8 Gearleg bolt 10 1080 7 Driveshaft key 10 1440 6 Gasket 10 1312 5 Zink anode 20 1180 4 Locknut 10 1260 3 Propeller was...