8
PJC211/212/221/222
2.0.2 - 2013
DISPLAY WHEN ALARMS:
When there is a problem or a fault, the panel will show this alarm situation by changing LCD display backlight to
red color.
The panel will also change to show “Alarm Info” on the bottom of the screen, indicating that by press-
ing the corresponding button below, you will get information about what the problem is (examples below).
Voltage below 9.3V/17.5V
(12V/24V system)
or temperature above 85
o
C (80
o
C for PPC800 FW V1.013 or
older/ SR150000 FW V1.006 or older): Single short beep every 2.4 seconds
Voltage below 8.9V/16.3V
(12V/24V system)
or temperature above 100
o
C (90
o
C for PPC800 FW V1.013 or
older/ SR150000 FW V1.006 or older): Two short beeps every 2.4 seconds
Voltage below 8.5V/15V
(12V/24V system)
or temperature above 115
o
C (100
o
C for PPC800 FW V1.013 or
older/ SR150000 FW V1.006 or older): Red backlight in display and continous short beeps.
If one or more of the thrusters enters an alarm state - Voltage below 8 Volts (both 12 and 24 Volt sys-
tems) or temperature above 130
o
C (110
o
C for PPC800 FW V1.013 or older/ SR150000 FW V1.006 or older):
Continuous beeps, and the “HOLD” function will be cancelled and both thrusters will stop. Temperature must drop
below 115
o
C (100
o
C for PPC800 FW V1.013 or older) before the thruster can be operated again.
STOP
front s_v strek_PJC222.pdf 1 04.11.2010 11:05:34
(Button below this
symbol pressed)
No. of alarms
Alarm code
Alarm description
Reset alarm
and Return
Use joystick to scroll if
more than two alarms
Scroll bar
Name and
location of
device
Refer to Alarm code overview/table on pages 18-19 for
full description on the different alarm codes.
When using the “HOLD” function,
the internal and external (if fitted) buzzer will give the following warning signals: