6
carrier must be notified within seven days of receiving the equipment.
The packaging material should be kept for later inspection.
2.3 Charger Storage
If the charger is not to be installed immediately it must be stored in stable position, and in a certain
temperature and humidity environment, the environmental conditions are as follows:
Temperature : -25°C to 60°C
Relative humidity: ≤95%, non
-condensing
The recommended storage temperature is between: 10°C to 30°C.
2.4 Installation environment
To ensure the safe and healthy use of the charger, the location should be appropriate. Not only to
maintain a clean working environment, avoiding moisture, flammable gases, flammable liquids or
corrosive substances; users can place them at designated locations by means of manpower or
equipment, but be careful to maintain the spacing around the charger, to facilitate air circulation
and heat dissipation.
The following points should be noted:
A minimum of one meter of space must be left in front of and behind the machine to ensure
adequate space for operation and maintenance.
The input cable for the AC enters from the bottom of the charger.
Input and output wiring check
To ensure the safety of personnel during the installation of the charger, it is important to ensure
that all connections are made in the following conditions:
●
Keep EVMS-150 installation area clean and dust free
●
All power cables are Proper length and diameter
●
Startup and operational checks are performed by authorized service personnel.
●
Confirm the input and output voltage and frequency of the charger
●
Ground connection in accordance with IEC standards or local regulations.