Sicma S.p.A.
Miglianico (CH)
page 18
If both edges of blades are
worn it is possible to proceed
with their sharpening.
In case blades are particularly
worn or damaged, replace
them referring to the suitable
spare parts catalog.
Fig. 5
Blades sharpening must be done with suitable machines
that can guarantee a correct sharpening which respect the
angles indicated (fig. 5).
Every time blades are removed (disassembling/reassembling), before starting the machine again, it
is advisable to check and adjust the distance between blade and bed knife.
To adjust bed knife position proceed as follows:
•
Loosen locking screws (4).
•
Rotate the rotor (1)
bringing the blades (2)
near the bed knife (3).
•
Adjust the position of the
bed knife (3) by means of
adjusting nuts (5) making
sure that distance between
blade and bed knife is
included between 1.6
(0.063”) and 3.2 mm
(0.126”).
•
Make sure that this
distance is the same for all
blades.
•
Block adjusting nuts (5)
and tighten locking screws
(4) with a torque wrench
as shown on table of page
5.