NOTE
Do not operate the teach-in button using sharp objects.
Please refer to the enclosed operating instructions for the IO-Link photoelectric sensor
for information about adjusting the IO-Link sensing range.
The sensor is adjusted and ready for operation.
WTx4Fx-xxxxxxA0Zxx:
Sensor which it is not possible to set: the sensor is adjusted and ready for operation.
6.4
Process data structure
WTV4FP-xxxxxxxxAxx:
A00
A70
A71
A72
A73
A75
IO-Link
V1.1
Process
data
2 bytes
4 bytes
Byte 0: bits 15... 8
Byte 1: bits 7... 0
Byte 0: bits 31...
24
Byte 1: bits 13...
16
Byte 2: bits 15...
8
Byte 3: bits 7... 0
Bit 0 / Data
type
Q
L1
/ Boolean
Bit 1 / Data
type
Q
L2
/ Boolean
Qint.1 /
Boolean
Q
L2
/ Boo‐
lean
Qint.1 / Boolean
Bit... /
Descrip‐
tion / Data
type
2 ...15 /
[empty]
2 ...15 /
[time
measure‐
ment
value] /
UInt 14
2 … 15 /
[counter
value] /
UInt 14
2 … 15 /
[length /
speed
measure‐
ment] /
SInt14
2 /
Qint.1 /
Boolean
2 … 7 / [empty]
Bit... /
Descrip‐
tion / Data
type
3 … 15 /
[time
measure‐
ment
value] /
UInt13
8 … 31 / [carrier
load] / UInt 24
7
Troubleshooting
The Troubleshooting table indicates measures to be taken if the sensor stops working.
Table 14: Troubleshooting
LED/fault pattern
Cause
Measures
Green LED flashes
IO-Link communication
None
Switching outputs do not
behave in accordance with
1. IO-Link communication
2. Change of the configuration
3. Short-circuit
1. None
2. Adjustment of the configura‐
tion
3. Check electrical connections
6
COMMISSIONING
28
O P E R A T I N G I N S T R U C T I O N S | WTV4F
8025302.1DTW /2022-02-14 | SICK
Subject to change without notice
en