Technical data
Description
Value
Electrical
Supply voltage
12 – 24 VDC ± 10%
Power consumption
2 W
Switch-on delay (WI180C-PB)
500 ms
Switch-on delay (overall system)
2000 ms
Profile
PROFIBUS DP-V1
Maximum number of modules to be con-
nected
16
Transmission rates in kbit/s
9.6/19.2/45.45/93.75/187.5/500/
1.500/3.000/6.000/12.000
Maximum distance between nodes
1.200 m @ 9.6 – 93.75 kbit/s
1.000 m @ 187.5 kbit/s
400 m @ 500 kbit/s
200 m @ 1.500 kbit/s
100 m @ 3.000 – 12.000 kbit/s
Process data
2x output, 1x input, 14 bit received light
Asynchronous data
Fieldbus index map,
Transmission interface
RS-485
LEDs
PWR, RUN, COM, ERR (3x green, 1x red)
Power supply
Male M8 plug connector, 4-pin
Other interfaces
Male bus connector, 5-pin, internal
system bus
D-sub, 9-pin, PROFIBUS
EMC
Noise immunity (Length of cable ≤30 m)
in accordance with EN 61000-6-2/
EN 61131-2
Emission
in accordance with EN 55011, class A
Product safety
Protection class
3
Short-circuit protection
in accordance with VDE 0160
Mechanical
Protection category
IP50
Sensitivity to vibrations
IEC 68, 10 – 55 Hz
Shock resistance
IEC 68, 500 m/s² (~50 G)
Housing material
Polycarbonate
Dimensions (HxWxD) in mm
39.2 x 102.55 x 39
Connections
M8, 4-pin, power supply
D-sub, 9-pin, PROFIBUS
Male bus connector, 5-pin, bus con
-
nector
Environmental
parameters
Air humidity (operation/storage)
35 – 85% relative humidity