Table 5: AC/DC
WS34-U2x0
WE34-R2x0
1
L1 / +
L1 / +
2
N / -
N / -
3
-
Relay
4
-
Relay
5
-
Relay
1
2
3
4
5
0.14 ... 1.5 mm
2
I
N
= 4 A
1
2
3
4
5
0.14 ... 1.5 mm
2
I
N
= 4 A
Table 6: AC/DC relay
Relay
H
D
3
WE34-R2x0
H
3
4
5
3
4
5
I
max.
= 4 A@250 V AC
4 A@24 V DC
0.125 A@250 V DC
UL: 4A @ 250 V AC, general
use
4A @ 250 V AC, resistive
(NO)
3A @ 250 V AC, resistive
(NC)
4A @ 24 V DC, NO, general
use
3A @ 24 V DC, NC, general
use
R300
B300 (NO contacts only)
D
3
4
5
3
4
5
7
Additional functions
Alarm
Alarm output: the sensor (WE34-Vxxx) features a pre-failure notification output (“Alarm”
in connection diagram [
see "WS/WE34-Bxxx, WS/WE34-Vxxx", page 7
]), which issues a
notification if the sensor is only ready for operation to a limited extent. Possible causes:
sensor is contaminated, sensor is out of alignment. PNP: Alarm
→
M signal reserve
> 50% LOW, NPN: Alarm
→
L+ signal reserve > 50% HIGH. The LED indicator flashes in
this case.