6
Center of optical axis, receiver (far range)
7
M5 threaded mounting hole, 6 mm deep
8
M5 threaded mounting hole, through-hole
9
M16 screw fixing and plug rotatable by 90°
Table 1: Display and operating elements
WT24-2Bx2x, -2Vx2x, -2Bx5x,
-2Vx5x
t
2
t
2
t
1
t
1
t
1
+ t
2
t
0
PNP
NPN
D
H
1
2
3
6
4
5
7
1
.0
1
Yellow LED indicator
2
Potentiometer: adjust‐
ing the sensing range
3
Switch: light (L) / dark
(D)
4
Switch: NPN / PNP
5
Potentiometer: adjust‐
ment of time delay t
2
6
Potentiometer: adjust‐
ment of time delay t
1
7
Potentiometer: adjust‐
ment of time stage
WT24-2Bx1x, -2Vx1x, -2Bx4x,
-2Vx4x
PNP
NPN
D
H
1
.0
1
2
3
4
1
Yellow LED indicator
2
Potentiometer: adjust‐
ing the sensing range
3
Switch: light (L) / dark
(D)
4
Switch: NPN / PNP
WT24-2Rx2x, -2Rx5x
t
2
t
2
t
1
t
1
t
1
+ t
2
t
0
D
H
1
.0
1
2
3
5
4
6
1
Yellow LED indicator
2
Potentiometer: adjust‐
ing the sensing range
3
Switch: light (L) / dark
(D)
4
Potentiometer: adjust‐
ment of time delay t
2
5
Potentiometer: adjust‐
ment of time delay t
1
6
Potentiometer: adjust‐
ment of time stage
WT24-2Rx1x, -2Rx4x
D
H
1
.0
1
2
3
1
Yellow LED indicator
2
Potentiometer: adjust‐
ing the sensing range
3
Switch: light (L) / dark
(D)
4
Mounting
Mount the sensor using a suitable mounting bracket (see the SICK range of accesso‐
ries).
Note the sensor's maximum permissible tightening torque of 2 Nm.
Note the preferred direction of the object relative to the sensor, cf.
5
Electrical installation
The sensors must be connected in a voltage-free state (U
V
= 0 V). The following informa‐
tion must be observed, depending on the connection type:
–
Plug connection: note pin assignment: when the lid is open, the male connector
can be swiveled horizontally and vertically.
–
Terminal connection: Note the permissible cable diameter of 5 to 10 mm. When
the lid is open, the M16 connector can be swiveled horizontally and vertically.
Unscrew the M16 connector and remove sealing plug. Lead voltage-free supply
cable through and connect sensor in accordance with
. Retighten
M16 connector with seal so that the IP enclosure rating of the device is ensured.
3
OPERATING AND STATUS INDICATORS
6
8008784.Z474 | SICK
Subject to change without notice